WARNING
Failure to open grill hood during the lighting
procedure could result in a fire or explosion
that could cause serious bodily injury, death,
or property damage.
Checking for LP gas leaks
Check the hose before using the outdoor cooking
gas appliance. If there is a significant excessive
wear, or if the hose is cut, it must be replaced before
the outdoor cooking gas appliance is put into
operation. Replace the hose assembly as specified
by the manufacturer.
1. Make a 50/50 (soap/water) mild soap solution.
2. open the door.
3. Turn the control knobs to full OFF position; then
turn gas ON at supply cylinder.
4. Check all connections from L.P. gas regulator and
supply cylinder up to and including the connection
to the manifold pipe assembly (the pipe that goes
to the burners). Soap bubbles will appear where a
leak is present.
5. If a leak is present, immediately turn off the gas
supply and tighten the leaky fittings. Turn the gas
back on and recheck.
6. If you have a gas connection leak, turn gas OFF
at supply cylinder, disconnect fuel line from your
grill and call 855-256-2160 or your gas supplier for
repair assistance.
7. Also apply soapy solution to the cylinder seams.
See below. If growing bubbles appear, shut
cylinder OFF and do not use or move it! Contact
an LP gas supplier or your fire department for
assistance.
Gas cylinder Leak Check
Gas Connection Leak Check
Grill Lighting Instruction
Grill Lighting Instructions for Main Burners
1. Do not smoke while lighting grill or checking
gas supply connections.
2. Be sure that LP gas cylinder is sufficiently full.
3. Be sure all gas connections are securely
tightened.
4. Turn on gas supply
5. Open the grill main hood.
6. Press the control knob and turn to MAX.
7. If the burner does not light in 5 seconds, turn
knob to OFF. Turn gas OFF at LP gas cylinder and
wait 5 minutes. Then turn gas ON at cylinder and
repeat step 6.
8. If burner still does not light, see Match Lighting
section and If Grill Still Fails to Light section on
following page.
9. If the burner flame is accidentally extinguished,
turn the knob to off. Turn off the gas in the LP gas
cylinder and wait for 5 minutes. Then turn on the
gas on the cylinder and repeat step 6.
20