1 Production Overview

 

The Exor eTOP Series 500 HMI products combine state-of-the-art features and top performance with an 

oustanding design. They are the ideal choice for all demanding HMI applications including factory and 

building automation.

The eTOP Series 500 HMI panels have been designed to run the JMobile software. 

•   Designed for use with JMobile HMI software.

•  Full vector graphic support. Native support of SVG graphic objects. Trasparency and alpha 

blending.

•  Full object dynamics: control visibility and transparency, move, resize, rotate any object on screen. 

Change properties of basic and complex objects.

•  TrueType fonts.

•  Multilanguage applications. Easily create and manage your applications in multiple languages to 

meet global requirements. Far East languages are supported. Tools available in JMobile Studio 

support easy third-party translations and help reducing development and maintenance costs of the 

application.

•  Data display in numerical, text, bargraph, analog gauges and graphic image formats. 

•  Rich set of state-of-the-art HMI features: data acquisition, alarm handling, scheduler and timed 

actions (daily and weekly schedulers, exception dates), recipes, users and passwords, RSS feeds, 

rotating menus.

•  Includes support for a wide range of communication drivers for Factory systems.

•  Multiple drivers communication capability.

•  Remote monitoring and control. Client-Server functionality.

•  On-line and Off-line simulation with JMobile Studio.

•  Powerful scripting language for automating HMI applications. Script debugging improves efficiency 

in application development.

•  Rich gallery of vector symbols and objects.
•  Optional plug-in modules for fieldbus systems, I/O and controllers.

Содержание eTOP506

Страница 1: ...eTOP Series 500 Operating Instructions User s Manual for eTOP Series 500 Touchscreen Products MANUGENETOP5xx Version 2 00 2018 EXOR International S p A...

Страница 2: ...ct to change without notice The information contained in this document is provided for informational purposes only While efforts were made to verify the accuracy of the information contained in this d...

Страница 3: ...specifications 8 4 Technical data 10 4 1 Dimensions 14 4 2 Installation environment 16 4 3 Installation procedure 17 5 Connections 18 5 1 Serial port 20 5 2 Ethernet port 21 5 3 Option plugin module...

Страница 4: ...els eTOP504 Operator interface with TFT color 4 3 display touchscreen eTOP506 Operator interface with TFT color 5 7 display touchscreen eTOP507 Operator interface with TFT color 7 widescreen display t...

Страница 5: ...ndications of attention are divided into three levels of severity DANGER indicates a failure to observe safety rules and such failure may cause death or serious injuries ATTENTION indicates a failure...

Страница 6: ...ations in multiple languages to meet global requirements Far East languages are supported Tools available in JMobile Studio support easy third party translations and help reducing development and main...

Страница 7: ...only in the case that special in measures are taken in order to ensure conformity to EN 61000 6 3 The products are in compliance with the Restrictions on Certain Hazardous Substances RoHS Directive 2...

Страница 8: ...panel has been tested using conditions equivalent to the standards shown in the Environmental conditions Even though the level of resistance unit is equivalent to these standards oils that should hav...

Страница 9: ...ype Time of continuos operation until the brightness of the backlight reaches 50 of the rated value when the sorrounding air temperature is 25 C see Note 1 Front foil 10 years if the surrounding air t...

Страница 10: ...ial Port RS 232 RS 485 RS 422 DB9 female software configurable RS 232 RS 485 RS 422 DB9 female software configurable Ethernet port 2 10 100 Mbit with integrated switch 2 10 100 Mbit with integrated sw...

Страница 11: ...ry Serial Port RS 232 RS 485 RS 422 DB9 female software configurable RS 232 RS 485 RS 422 DB9 female software configurable Ethernet port 2 10 100 Mbit with integrated switch 2 10 100 Mbit with integra...

Страница 12: ...Port RS 232 RS 485 RS 422 DB9 female software configurable RS 232 RS 485 RS 422 DB9 female software configurable Ethernet port 2 10 100 Mbit with integrated switch 2 10 100 Mbit with integrated switc...

Страница 13: ...rial Port RS 232 RS 485 RS 422 DB9 female software configurable RS 232 RS 485 RS 422 DB9 female software configurable Ethernet port 2 10 100 Mbit with integrated switch 2 10 100 Mbit with integrated s...

Страница 14: ...GENETOP5xx Version 2 00 2018 EXOR International S p A Subject to change without notice 4 1 Dimensions 4 Technical Data MODEL A B C D E F eTOP504 149mm 5 86 109mm 4 29 136mm 5 35 96mm 3 78 56mm 2 40 4m...

Страница 15: ...mm 7 36 147mm 5 79 176mm 6 90 136mm 5 35 47mm 1 85 4mm 0 16 eTOP507M 187mm 7 36 147mm 5 79 176mm 6 90 136mm 5 35 47mm 1 82 4mm 0 16 eTOP510 287mm 11 30 232mm 9 13 276mm 10 86 221mm 8 70 56mm 2 20 4mm...

Страница 16: ...el protection classifications proper installation procedure must be followed the borders of the cutout must be flat screw up each fixing screw until the plastic bezel corner get in contact with the pa...

Страница 17: ...nternational S p A Subject to change without notice 4 3 Installation Procedure Place the fixing brackets as shown in figure Fig 4 3 Fig 4 3 4 Technical Data CAUTION Screw each fixing screw until the b...

Страница 18: ...x Version 2 00 2018 EXOR International S p A Subject to change without notice 1 Serial Port 2 2x Ethernet Port 3 USB Port 4 Power Supply 5 Expansion slot for Plugin module 6 SD Card Slot Fig 5 1 eTOP5...

Страница 19: ...rnational S p A Subject to change without notice 1 Serial Port 2 2x Ethernet Port 3 USB Port version 2 0 1 1 4 USB Port version 2 0 High speed only 5 Power Supply 6 2x Expansion slot for Plugin module...

Страница 20: ...gnals in the PLC port connector RS 232 RS 422 RS 485 Pin Description 1 GND 2 3 CHA 4 CHB 5 6 5V output 7 CHB 8 CHA 9 The serial port is software programmable Make sure you select the appropriate inter...

Страница 21: ...S p A Subject to change without notice 1 8 ON No activity BLINKING Activity 5 Connections 5 2 Ethernet Port The Ethernet port have two status indicators Please see description in figure OFF Valid link...

Страница 22: ...s have several optional plugin module multiple modules configurations are possible Slot 2 and Slot 4 are available only if plugin module has the bus extension connector Each slot carries three communi...

Страница 23: ...2 Serial Y PLCM05 CODESYS V2 License 1 Y PLCM06 Profibus DP 1 SPI N PLIO03 Multifunction I O 1 SPI N PLIO06 Compact I O 2 SPI N Max modules refers to max number of modules can be plugged into the HMI...

Страница 24: ...power supply circuit may be floating or grounded In the latter case connect to ground the power source common as shown in figure see below with a dashed line When using the floating power scheme note...

Страница 25: ...ormation is maintained by the battery hardware real time clock date and time Charge At first installation must be charged for 48 hours When the battery is fully charged it ensures a period of 3 months...

Страница 26: ...uter running Microsoft Windows There are two options to transfer a JMobile application project to a HMI device Ethernet Connect the HMI device to the computer with an Ethernet network connection From...

Страница 27: ...ive item to start the associated function System Settings has two modes of operation User Mode JMobile runtime is running or the HMI device is in factory default status System Mode JMobile runtime is...

Страница 28: ...installed Network configure IP Address of Ethernet interface BSP settings show the BSP Board Support Package version check the operating hours for the device and for the display backlight manage the b...

Страница 29: ...BSP Upload Bootloader reserved to authorized technical personnel Upload Configuration OS reserved to authorized technical personnel Upload Main OS reserved to authorized technical personnel Upload Spl...

Страница 30: ...NUGENETOP5xx Version 2 00 2018 EXOR International S p A Subject to change without notice 11 LED Indicator on Front Panel The table below shows the symbol of the LED indicator dedicated to special func...

Страница 31: ...31 MANUGENETOP5xx Version 2 00 2018 EXOR International S p A Subject to change without notice To repack the unit please follow the instructions backwards 12 Unpacking and packing instructions...

Отзывы: