Menu sequence and structure •
47
3110086 EHC20 UK 110515
2. Statistics
The ”2. Statistics” menu is used for function control and long-term
monitoring of the system.
The menu can be exited by pressing ”esc” or selecting ”Exit statistics”.
In order to evaluate system data, the controller clock must be set correctly. Improper operation
or an incorrect time may result in data being deleted, recorded incorrectly or overwritten.
The manufacturer accepts no liability for the data recorded.
2.1 Operating hours
Shows the number of hours that the solar pump connected to the controller has been in operation. Various time ranges
(day-years) are available.
2.2 Heat quantity
Shows the system’s heat yield.
2.3 Graphic overview
The data set out under 2.1-2.2 are presented clearly in the form of a bar chart here. Various time ranges are available for
comparison. You can scroll using the two buttons on the left.
2.4 Reports
Shows the last 20 system reports issued along with details of the date and time.
2.5 Reset / delete
Allows you to reset and delete individual statistics. If you select ”All statistics”, everything apart from the error list will be deleted.
3. Operating mode
In the ”3. Operating mode” menu, you can not only select the automatic
mode but also switch off the controller or switch to a manual operating
mode.
You can exit the menu by pressing ”esc” or selecting ”Exit statistics”.