6.0 Troubleshooting
6.1 Mechanical Problems
This section will provide you with a helpful guideline to troubleshooting
various problems that may occur during operation and installation of your
FTX actuator.
Symptom/ Problem
Possible Cause
Problem Solution
Abnormally loud whining
coming from actuator.
Misalignment or Side
Load
Check alignment with application,
remount actuator if necessary.
Remove side load.
Abnormally loud whining
coming from actuator.
Improper servo tuning
Consult tuning guidelines for servo
motor and drive.
Actuator motor rotates but
output rod does not
extend or retract.
Belt or inline coupling
failure
Disconnect power to motor, remove
belt cover and inspect belt or inline
coupling. Replace if necessary.
Motor does not operate.
Motor electrical
problem
Consult motor manufacturer.
Output rod has excessive
rotation, or rotates but
does not extend.
Anti-rotate failure
Replace anti-rotate mechanism
Excessive motor current
to operate actuator.
An internal
mechanism binding,
application binding,
roller screw failure.
Operation over peak
load rating.
Consult Exlar
6.2 Electrical Problems
All electrical problems associated with the motor used to drive the
roller screw in an FTX actuator should be taken up with that motor
manufacturer. Exlar will assist in contacting the appropriate person.
If an externally mounted limit switch is not operating properly, check all
power connections to the switch and make sure that the switch is wired
properly.
Refer to the diagram in section 4.3 for further details regarding
wiring.