DEScRIpTIon of fUncTIonS

The charger is fully automatic and programmed for advanced 
charging of lead-acid batteries between 1 and 85 Ah. The inte-
grated safety functions that are intended to limit overcharging 
could interrupt the charge process when charging larger  
batteries than the charger is intended for.

This product is equipped with a temperature compensator, 
because temperature is highly significant for batteries’ ability to 
receive charge. The temperature sensor is integrated in one of  
the terminal clamps. Thanks to our temperature compensation,  
the common problems involved in insufficient charging in cold 
weather and overcharging at high temperatures are eliminated.

The charging curve is shown on the attached diagram, which 
shows how the charge is split into five different steps that are 
adapted to the battery type and size. The charger must be con-
nected to the battery according to the instructions in ’getting start-
ed’. After it is connected, it will charge the battery and maintain it 
fully charged with the continual maintenance charging as long as  
it is connected to the mains power.

In order to minimise the risk of overcharging an incorrect type 
of battery, the charger is equipped with a cut-out function that 
interrupts charging, at the same time as the fault is shown by the 
LED shining a constant red. NOTE: This fault alarm can be trig-
gered during charging of batteries that have capacities above the 

I (A)

(h)

STEP

1

STEP

2

STEP

3

STEP

4

STEP

5

U (V)

Volt (V) 

Ampere (A) 

Continues on next page.

Содержание 12/4

Страница 1: ...1 USER GUIDE 12 V Lead acid batteries 1 85 Ah GB ...

Страница 2: ...an be stored in its packaging so that you protect the charger keep cables tidy keep the user guide safe and at the same time protect the environment Discarded packaging can be recycled Read the safety instructions and user guide carefully If you follow the instructions you will benefit from a high performance charger that will give excellent service for many years to come For more information abou...

Страница 3: ...re compen sator provides optimum charging for lead acid batteries within a range of 1 85 Ah and temperature 1 Connect the charger s mains plug to a power socket 2 Connect the charger s red cable clamp to the battery s positive ter minal post and the black cable clamp to the battery s negative terminal post 3 When the green lamp shines the battery is fully charged GETTING STARTED MP Error ...

Страница 4: ...ll begin automatically after 3 seconds when the LED will stop flashing and changes to a constant orange At the same time the lamp on the front of the charger will go out 5 When charging is complete as indicated by a constant green light the charger clamps can either be disconnected from the battery terminals or remain connected for permanent main tenance of charge If the charger remains connected ...

Страница 5: ...f water and contact a doctor immediately Never charge a frozen battery Never position the charger above the battery during charging Do not cover the charger This charger is protected against overheating If the ambient temperature is too high the charging current is reduced During the charge the charger may intermittently provide a 15 5 V charge voltage Ensure that no equipment which may be damaged...

Страница 6: ...emperatures are eliminated The charging curve is shown on the attached diagram which shows how the charge is split into five different steps that are adapted to the battery type and size The charger must be con nected to the battery according to the instructions in getting start ed After it is connected it will charge the battery and maintain it fully charged with the continual maintenance chargin...

Страница 7: ...ct the charger then connect the batteries to each other by connecting their positive terminal posts together using a jump cable and then connecting the negative terminal posts using the other jump cable Then connect the charger and retry the process If charging starts disconnect the jump leads and allow charging to continue until the battery is fully charged If charging does not begin the battery ...

Страница 8: ...afety reasons Action If possible disconnect the parallel load and repeat charging or purchase a larger charger suitable for both charge and drain Probable cause 3 Battery is too large The battery is larger than the recommended size for the charger which means that the charge could not be completed within the time constraints that are built into the battery for safety reasons Action Repeat charging...

Страница 9: ...Uh Uh 13 7 V Maintenance charge Lead acid battery types AGM GEL standard batteries Battery capacity 1 85 Ah Cabling Battery cable 1700 mm Power cable 2x0 75 mm2 1800 mm Dimensions LxWxH 225x50x50 mm International Protection rating IP54 Weight 0 5 kg CE Manufacturer s declaration Manufacturer EXIDE Technologies Kungälv Sweden and Primepower AB Växjö Sweden Product Battery charger EXIDE 12 4 The man...

Страница 10: ...nufacture or distribution the mandatory guarantee rights apply The guarantee will no longer be valid if the charger has not been handled correctly or opened or repaired by any other than Exide Technologies or its authorized representatives Exide Technologies is not responsible for other costs than those stated above i e no potential consequential costs Nor is Exide Technologies liable under any ot...

Отзывы: