recommended battery size or in connection with other equipment 
drawing current (parallel load) being connected to the battery dur-
ing charging.

Batteries can be damaged by being charged at high temperatures, 
so the charger has been fitted with a safety function that interrupts 
charging when temperatures are too high, approx. 50 °C.

Information about faults and fault indications is explained in the 
table below.

Continues on next page.

fAULT InDIcATIonS AnD TRoUBLEShooTInG

Fault: 

Charging does not start, i.e. the lamp continues to light, 

and the LED does not change to the constant orange light.

Probable cause: 

The battery voltage is too low to start the 

charger. This may be because the battery is worn or faulty or  
has been completely discharged.

Action: 

Sometimes it may help to connect a functioning battery 

in parallel, as when using jump cables. If so: first disconnect the 
charger, then connect the batteries to each other by connecting 
their positive terminal posts (+) together using a jump cable, and 
then connecting the negative terminal posts (-) using the other 
jump cable. Then connect the charger and retry the process. If 
charging starts, disconnect the jump leads and allow charging 
to continue until the battery is fully charged. If charging does not 
begin the battery is probably defective and should be replaced.

Fault: 

The LED shows constant red when the charger cable 

clamps are connected to the battery terminal posts.

Probable cause: 

If the cable clamps are incorrectly connected 

to the battery, the polarity reversal protection will be activated and 
charging will not start.

Action: 

Check that the charger is connected using the correct polarity.

1.

2.

Fault: 

Charging started normally, but did not complete. Instead, 

the LED changed to constant red light and charging is terminated.

Probable cause 1: 

Defective or worn battery. The battery has a 

fault that does not permit it to be charged, e.g. a short circuit.

Action: 

Replace the battery. 

3.

Содержание 12/4

Страница 1: ...1 USER GUIDE 12 V Lead acid batteries 1 85 Ah GB ...

Страница 2: ...an be stored in its packaging so that you protect the charger keep cables tidy keep the user guide safe and at the same time protect the environment Discarded packaging can be recycled Read the safety instructions and user guide carefully If you follow the instructions you will benefit from a high performance charger that will give excellent service for many years to come For more information abou...

Страница 3: ...re compen sator provides optimum charging for lead acid batteries within a range of 1 85 Ah and temperature 1 Connect the charger s mains plug to a power socket 2 Connect the charger s red cable clamp to the battery s positive ter minal post and the black cable clamp to the battery s negative terminal post 3 When the green lamp shines the battery is fully charged GETTING STARTED MP Error ...

Страница 4: ...ll begin automatically after 3 seconds when the LED will stop flashing and changes to a constant orange At the same time the lamp on the front of the charger will go out 5 When charging is complete as indicated by a constant green light the charger clamps can either be disconnected from the battery terminals or remain connected for permanent main tenance of charge If the charger remains connected ...

Страница 5: ...f water and contact a doctor immediately Never charge a frozen battery Never position the charger above the battery during charging Do not cover the charger This charger is protected against overheating If the ambient temperature is too high the charging current is reduced During the charge the charger may intermittently provide a 15 5 V charge voltage Ensure that no equipment which may be damaged...

Страница 6: ...emperatures are eliminated The charging curve is shown on the attached diagram which shows how the charge is split into five different steps that are adapted to the battery type and size The charger must be con nected to the battery according to the instructions in getting start ed After it is connected it will charge the battery and maintain it fully charged with the continual maintenance chargin...

Страница 7: ...ct the charger then connect the batteries to each other by connecting their positive terminal posts together using a jump cable and then connecting the negative terminal posts using the other jump cable Then connect the charger and retry the process If charging starts disconnect the jump leads and allow charging to continue until the battery is fully charged If charging does not begin the battery ...

Страница 8: ...afety reasons Action If possible disconnect the parallel load and repeat charging or purchase a larger charger suitable for both charge and drain Probable cause 3 Battery is too large The battery is larger than the recommended size for the charger which means that the charge could not be completed within the time constraints that are built into the battery for safety reasons Action Repeat charging...

Страница 9: ...Uh Uh 13 7 V Maintenance charge Lead acid battery types AGM GEL standard batteries Battery capacity 1 85 Ah Cabling Battery cable 1700 mm Power cable 2x0 75 mm2 1800 mm Dimensions LxWxH 225x50x50 mm International Protection rating IP54 Weight 0 5 kg CE Manufacturer s declaration Manufacturer EXIDE Technologies Kungälv Sweden and Primepower AB Växjö Sweden Product Battery charger EXIDE 12 4 The man...

Страница 10: ...nufacture or distribution the mandatory guarantee rights apply The guarantee will no longer be valid if the charger has not been handled correctly or opened or repaired by any other than Exide Technologies or its authorized representatives Exide Technologies is not responsible for other costs than those stated above i e no potential consequential costs Nor is Exide Technologies liable under any ot...

Отзывы: