8
mAInTEnAncE/AccESSoRIES
The charger is fully maintenance-free. Note that there are no user-
serviceable parts, and opening this product (charger) will invalidate
the warranty. If the mains cable is damaged it must be replaced by
the retailer. Do not use the charger if its cables, terminal clamps
or casing are damaged. The case may be cleaned using a soft,
damp rag and a mild detergent. The charger must be disconnected
from the mains when being cleaned. The charger is supplied with
terminal clamps on each cable. Connecting cables with ring cable
connectors for permanent fixture are enclosed in the box.
Probable cause 2:
Parallel load. If a piece of equipment that drains
current is connected to the battery, there is a risk that the capacity
of the charger is not sufficient to charge the battery within the time
constraints that are built into the charger for safety reasons.
Action:
If possible, disconnect the parallel load and repeat charging,
or purchase a larger charger suitable for both charge and drain.
Probable cause 3:
Battery is too large. The battery is larger than
the recommended size for the charger, which means that the
charge could not be completed within the time constraints that
are built into the battery for safety reasons.
Action:
Repeat charging.
Probable cause 4:
The high temperature cut-out that monitors
the battery temperature has been triggered. The reason for the
high temperature could be that the battery has an internal fault,
or that the ambient temperature is high.
Action:
If charging is carried out at room temperature, the high
temperature is probably caused by a battery fault or wear.
The battery should be replaced. If charging is taking place at a
high ambient temperature, charging may be resumed when the
battery has cooled to room temperature.
Fault:
The lamp does not come on when the charger is power
cable plugged into the mains socket.
Probable cause:
No power in mains socket. Lamp blown.
4.