3002367-2008-06-01.fm
GB - Product information
39/56
• Connect the plug on the supply cable to a plug socket.
• Check that the power diode (D) is illuminated (drawing 6)
Warning: current is now connected to the unit.
NB. Always switch off the electricity supply before opening the chimney fan.
•
Remove the following two parts from
the chimney fan cable supplied.
•
Fit the coupling from the control unit
screw joint to the armoured hose.
•
The black clamping ring must be posi-
tioned on the outside of the armoured
hose.
•
Fit the seal from the screw connector
to the red silicon cable.
•
Tighten the coupling.
•
Loosen the screws on the terminals
(8-10)
•
Hold the wires in place with a pair of
pliers and tighten the screws
•
The wire colours from left to right are:
brown, blue, yellow/green.
Temperature sensor (Drawing 1 and 2)
•
Loosen the coupling
•
Pull the cable through the screw joint
•
Tighten the coupling fully
•
Loosen the screws on the terminals
(6-7)
•
Hold the wires in place with a pair of
pliers and tighten the screws
•
The wire colours from left to right are:
brown, blue
•
See also “Example 2” next page