
Pattern Tabs
256
IQS-8500 Series and IQS-8120NGE/8130NGE
Pattern TX
Error Injection
Allows selection and configuration of a manual or automated pattern error
that will be generated.
Type
: The only available type of pattern error is
Bit Error
.
Amount
: Select the amount of error to be generated. Choices are
1
through
50
. The default setting is
1
.
Send
button: Press
Send
to manually generate the pattern error according
to the pattern error type and the amount.
Rate
: Press the
Rate
field to select the rate for the selected pattern error.
Choices are:
1.0E-02
,
1.0E-03
,
1.0E-04
,
1.0E-05
,
1.0E-06
,
1.0E-07
,
1.0E-08
,
1.0E-09
, or user definable from
1.0E-09
to
1.0E-02
. The default setting is
1.0E-04
.
Continuous
: Generates the Bit error for each bit generated when the
Continuous
check box is selected while the
On/Off
button is enabled
(On). The
Continuous
check box is cleared by default.
On/Off
button: The On/Off button is used to activate/deactivate the
selected automated pattern error at the rate specified or for each bit
generated when the
Continuous
check box is selected. This setting is
disabled (Off) by default.
Note:
Manual and Automated error injection can run simultaneously.
Содержание IQS-8120NGE
Страница 1: ...User Guide IQS 8500 Series and IQS 8120NGE 8130NGE for IQS 600 Ethernet and Fibre Channel Application...
Страница 14: ......
Страница 18: ......
Страница 22: ......
Страница 24: ......
Страница 48: ......
Страница 134: ......
Страница 214: ......
Страница 252: ......
Страница 312: ......
Страница 438: ......
Страница 460: ......
Страница 468: ......
Страница 478: ......