• Example 2 (Offset use): Read four Modbus slaves from two masters. Two of the slaves have
the ID # 1 and the other two the ID # 2.
The devices will be connected as follows to the device:
• Port A: Master 1.
• Port B: Master 2.
• Port C: First pair of slaves with ID # 1 and # 2.
• Port D: Second pair of slaves with ID # 1 and # 2.
The configuration will be as follows:
SRANGEADD:A,1,2,C,0
SRANGEADD:A,3,4,D,2
SRANGEADD:B,1,2,C,0
SRANGEADD:B,3,4,D,2
In this way, both masters will be able to access the first pair of slaves using ID # 1 and # 2,