background image

1

9

 

|

 

P

 

a

 

g

 

e

INSTALLATION

Installation

 

must

 

be

 

performed

 

in

 

accordance

 

with

 

Local

 

NEC

 

codes.

Preparing

 

Pool

 

Water:

 

The

 

pool’s

 

chemistry

 

must

 

be

 

balanced

 

BEFORE

 

activating

 

the

 

Excelpool

 

System.

 

It

 

is

 

recommended

 

that

 

you

 

consult

 

a

 

pool

 

professional

 

for

 

the

 

initial

 

balancing

 

each

 

season.

 

NOTE:

 

At

 

the

 

beginning

 

of

 

each

 

season,add

 

metal

 

remover

 

and

 

polymer

 

based

 

(non-copper)

 

algaecide

 

to

 

the

 

pool,

 

per

 

manufacturer’s

 

instructions.

 

This

 

ensures

 

a

 

quick,

 

trouble

 

free

 

transfer

 

to

 

the

 

Excelpool

 

System

 

system.

Mounting

 

the

 

Excel

P

ool

 

System

 

Control

The

 

Excelpool

 

System

 

is

 

contained

 

in

 

a

 

rain

 

tight

 

enclosure

 

that

 

is

 

suitable

 

for

 

outdoor

 

mounting.

 

The

 

control

 

must

 

be

 

mounted

 

a

 

minimum

 

of

 

5

 

ft

 

(2

 

meters)

 

horizontal

 

distance

 

(or

 

more

 

if

 

local

 

codes

 

require)

 

from

 

the

 

pool/spa.

The

 

control

 

is

 

designed

 

to

 

mount

 

vertically

 

on

 

a

 

flat

 

surface

 

with

 

the

 

knockouts

 

facing

 

downward.

 

Because

 

the

 

enclosure

 

also

 

acts

 

as

 

a

 

heat

 

sink

 

(disperses

 

heat

 

from

 

inside

 

the

 

box),

 

it

 

is

 

important

 

not

 

to

 

block

 

the

 

four

 

sides

 

of

 

the

 

control.

Do

 

not

 

mount

 

the

 

Excelpool

 

System

 

in

 

a

 

panel

 

or

 

tightly

 

enclosed

 

space.

Plumbing

Ensure that the Excelpool System installation does not constitute 

a cross connection with the local potable water supply. Consult 

local plumbing codes.

The cell and flow switch are plumbed in the return line to the pool. 

Install after (downstream) all the pool equipment (filter, heater, 

solar, etc.). The kit included in the Excelpool System provides the 

necessary plumbing components for:

• 2” (51mm) rigid PVC piping installation for in ground pools

• 1 1/2-1 1/4 (38-32mm) flexible hose connections for

above ground pools

Содержание Excelpool Salt System

Страница 1: ...ystem Saltwater Chlorine Generator Installation and Operation Manual IN ORDER NOT TO VOID WARRANTY READ MANUAL BEFORE INSTALLATION Not following proper installation and or proper use guidelines may vo...

Страница 2: ...rdous voltage can shock burn and cause death or serious property damage NOTICE A licensed electrician must do all wiring WARNING Risk of Electric Shock Failure to bond all electrical equipment to pool...

Страница 3: ...nel To reduce the risk of electric shock this terminal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the ci...

Страница 4: ...he appropriate chlorine output for your pool suggest at 6 hours per day Pump running 24 hours day 25 Chlorine Output 6hr cell run time per day at 25 Pump running 20 hours day 30 Chlorine Output 6hr ce...

Страница 5: ...SAVE THESE INSTRUCTIONS Table of Contents OPERATION General 5 Water chemistry 5 Controls 12 Maintenance 16 INSTALLATION Mounting 19 Plumbing 19 Wiring 21 TROUBLESHOOTING Troubleshooting 25 WARRANTY Wa...

Страница 6: ...eanliness Note It is not recommended using the Excelpool System to generate Bromine If your pool has natural stone as coping or decking please check with a stone installation specialist for the mainte...

Страница 7: ...to 2 0 best SATURATION INDEX The saturation index Si relates to the calcium and alkalinity in the water and is an indicator of the pool water balance Your water is properly balanced if the Si is 0 2...

Страница 8: ...se Measure pool pH temperature calcium hardness and total alkalinity Use the chart above to determine Ti Ci and Ai from your measurements Insert values of pH Ti Ci and Ai into the above equation If Si...

Страница 9: ...the same TYPE OF SALT TO USE It is important to use only sodium chloride NaCl that is 99 pure This is common food quality or water softener salt available in 40 80 lb bag at your local store It is als...

Страница 10: ...olving process do not allow the salt to sit in a pile on the bottom of the pool ON ANY POOL DO NOT ADD SALT DIRECTLY TO THE SKIMMERS OR DIRECTLY ONTO THE MAIN DRAIN THIS WILL SHUT DOWN OR SHORTEN THE...

Страница 11: ...10 P a g e POUNDS and Kg OF SALT NEEDED FOR 3200 PPM Gallons and Liters of Pool Spa water...

Страница 12: ...cid level when testing for salt This test should be done at least once per month Use the chart below to determine how much stabilizer must be added to raise the level to 80 ppm POUNDS and Kg OF STABIL...

Страница 13: ...SUPER CHLORINATE When you have an abnormally high bather load heavy rainfall cloudy water conditions or any other condition which requires that a large amount of purification be introduced set the Ma...

Страница 14: ...luminates during Super Chlorination See description above REMOTE CONTROLLED The part is controlled by a remote control system NO FLOW When illuminated the flow switch has detected no flow and Excelpoo...

Страница 15: ...he Salt Display shows the current salt concentration of the pool water Readings are in ppm parts per million If Metric units grams per liter are preferred push the diagnostic button next to the displa...

Страница 16: ...ton the display will revert back to the default salt display Also if the button is not pushed for 30 seconds the display will revert back too Filter time each day hours The amount of salt in the pool...

Страница 17: ...flashing the Inspect Cell LED after approximately 500 hours of operation After you inspect the cell and clean if necessary press the small diagnostic button next to the display for 3 seconds to stop t...

Страница 18: ...NOT USE A METAL SCRAPER AS THIS WILL SCRATCH THE FINISH AND DAMAGE THE PLATES Note that a buildup on the cell indicates that there is an unusually high calcium level in the pool old pool water is usu...

Страница 19: ...at soaking and rinsing Replace cell and inspect again periodically WINTERIZING The Excelpool System electrolytic cell and flow detection switch will be damaged by freezing water similar to other pool...

Страница 20: ...izontal distance or more if local codes require from the pool spa The control is designed to mount vertically on a flat surface with the knockouts facing downward Because the enclosure also acts as a...

Страница 21: ...ocated on the side points in the same direction of water flow Electrolytic Cell Install using the unions provided Tighten by HAND for a watertight seal For pool spa combination systems with spillover...

Страница 22: ...Excelpool System to the LOAD SIDE of the filter pump timer It is very important that the Excelpool System is powered only when the pump is running Refer to the wiring label on Excelpool System as well...

Страница 23: ...to a circuit protected by a class A ground fault interrupter Be sure to connect the GROUND wire to the green ground screw terminal located on the INSIDE WALL of the enclosure Note Wire the pump direct...

Страница 24: ...The flow switch plugs into a connector similar to a telephone jack located outside on the bottom of the enclosure Refer to the diagram below for the location of these connections Input power for use w...

Страница 25: ...Attach wires to proper screw terminals as show below Pentair Attach wires to opposite numbered screw terminals as shown below Note that the colors marked on the Pentair PCB do not match the Excelpool...

Страница 26: ...Software revision level 8 Cell type On the 8th push of the button the display will revert back to the default salt display Also if the button is not pushed for 30 seconds the display will revert back...

Страница 27: ...pa If salt level is low add salt according to chart on page 10 Before adding large quantities of salt it is advisable to have your salt level professionally checked 5 High Salt LED illuminated Check s...

Страница 28: ...desired chlorine levels Adjust pH levels to re balance water Warm pool water increases chlorine demand increase Desired Level or filter run time Cold water below 50 F can cause Excelpool System to sto...

Страница 29: ...ted warranty is extended exclusively to the original purchaser of the Excelpool System and is non transferable Excelpool System is intended for residential pool use and any commercial application void...

Страница 30: ...e service work Some states do not allow the exclusion of limitations of incidental or consequential damages Listed exclusions and limitations may not apply to you Problems arising from failure to main...

Страница 31: ...NOTES 30 P a g e...

Страница 32: ...excelpoolproducts com...

Отзывы: