2
3
|
P
a
g
e
Bonding:
A
lug
used
for
bonding
is
attached
to
the
bottom
of
the
Excelpool
System
enclosure
(see
diagram
below).
The
Excelpool
System
must
be
bonded
with
an
8
AWG
copper
wire
(6
AWG
Canada)
to
the
pool
bonding
system.
Electrolytic
Cell
and
Flow
Switch:
The
electrolytic
cell
and
flow
switch
cables
are
terminated
with
connectors
that
plug
into
the
Excelpool
System
for
easy
attachment
and
removal.
The
door
of
the
Excelpool
System
must
be
open
to
access
the
cell
cable
connector.
The
flow
switch
plugs
into
a
connector
(similar
to
a
telephone
jack)
located
outside,
on
the
bottom
of
the
enclosure.
Refer
to
the
diagram
below
for
the
location
of
these
connections.
I
nput
power
for
use
with
Goldline,
Pentair
and
Polaris
controls:
Wire
the
Excelpool
System
DIRECTLY
TO
120/240VAC
POWER
(not
through
timer
or
relay).
Optional
Goldline,
Pentair
and
Polaris
controls:
The
Goldline,
Pentair
and
Polaris
controls
use
a
4
wire
connection
to
communicate
to
the
Excelpool
System
and
can
be
wire
up
to
500’
apart.
Any
outdoor
rated
4
conductor
cable
can
be
used.
Refer
to
each
manufacturer’s
instructions
and
the
wiring
diagrams
below
for
proper wiring connection to the Excelpool
System.