Page 3
Installation
GENERAL INSTALLATION & SERVICE WARNINGS
The control valve, fittings and/or bypass are designed to accommodate minor plumbing
misalignments but are not designed to support the weight of a system or the plumbing.
Do not use Vaseline, oils, other hydrocarbon lubricants or spray silicone anywhere. A silicone
lubricant may be used on black o-rings but is not necessary.
Avoid any type of lubricants,
including silicone, on red or clear lip seals.
Do not use pipe dope or other sealants on threads.
Teflon tape must be used on the
threads of the 1” NPT elbow or the ¼” NPT connection and on the threads for the drain line
connection. Teflon tape is not necessary on the nut connections or caps because o-ring seals are
used. The nuts and caps are designed to be unscrewed or tightened by hand or with the special
plastic Service Wrench, #V3193. If necessary pliers can be used to unscrew the nut or cap.
Do
not use a pipe wrench
to tighten or loosen nuts or caps.
Do not place screwdriver in slots
on caps and/or tap with a hammer.
SITE REQUIREMENTS:
•
Water pressure, 20-125 psi
•
Current draw is 0.25 ampers
•
Water temperature (to 30C) or (40 to 100F)
•
A 15-foot power cord is furnished
•
The tank should be on a firm, level surface
•
The plug-in transformer is for dry locations only
•
Electrical: Use a 115/120v, 60Hz uninterrupted
outlet
•
Batteries are not used
1.
The distance between the drain and the water conditioner should be as short as possible.
All plumbing should be done in accordance with local plumbing codes. NOTE: Maximum
head 15 10’ or 3 meters.
2.
Since salt must be periodically added to the brine tank, it should be located where it is
easily accessible.
3.
Do not install any water conditioner with less than 10 feet of piping between its outlet
and the inlet of a water heater.
4.
Do not locate unit where it or its connections (including the drain and overflow lines) will
ever be subjected to room temperatures under 34F.
Содержание CHLOR-A-SOFT
Страница 6: ...Page 6 ...
Страница 7: ...Page 7 ...
Страница 14: ...Page 14 Drawings and Part Numbers ...