Page 13
Installers Displays/Settings
STEP
1I
–
Press NEXT and UP simultaneously for 3 seconds.
STEP 2I
– Hardness: Set the amount of hardness in grains of hardness as
calcium carbonate per gallon using the DOWN or UP buttons. The default is 20
with value ranges from 1 to 150 in 1 grain increments. Note the grains per gallon
can be increased if soluble iron needs to be reduced. This display will show “-NA-
“if “FILTER” is selected in Step 2F or if “AUTO” is not selected in Step 6S. Press
NEXT to go to step 3I. Press REGEN to exit Installer Displays/Settings.
STEP 3I
– Day Override: When gallon capacity is set to off, sets the number of
days between regenerations. When gallon capacity is set to AUTO or to a
number, sets the maximum number of days between regenerations. If value set
to “OFF” regeneration initiation is based solely on gallons used. If value is set as
a number (allowable range from 1 to28) a regeneration initiation will be called
for on that day even if sufficient number of gallons were not used to call for
regeneration. Set Day Override using down or up buttons:
•
Number of days between regeneration (1 to 28); or
•
“OFF”.
See table 12 for more detail on softener setup and Table 13 for more detail on
filter setup. Press NEXT to go to step 4I. Press REGEN to return to previous step.
STEP 4I
– Next Regeneration Time (hour): Set the hour of day for regeneration
using down or up buttons. AM/PM toggles after 12. The default time is 2:00 a.m.
This display will show “REGEN on 0 GAL” if”on0” is selected in Step 7F. Press
NEXT to go to step 5I. Press REGEN to return to previous step.
STEP 5I
– Next Regeneration Time (minutes): Set the minutes of day for
regeneration using down or up buttons. This display will not be shown if “on 0” is
selected in Step 9S or Step 7F. Press NEXT to exit Installer Displays/Settings.
Press REGEN to return to previous step.
To initiate a manual regeneration immediately, press and hold the “REGEN”
button for three seconds. The system will begin to regenerate immediately. The
control valve may be stepped through the various regeneration cycles by
pressing the “REGEN” button.