Section 7  Handling and Storage

Handling requirements

: Ensure there is exhaust ventilation in the area. 

Avoid the formation or spread of dust in the air. Avoid direct contact with 

the substance.

Storage conditions

: Store in cool, well ventilated area. Keep container 

tightly closed.

Practices

: Maintain general industrial hygiene practices when using this 

product.

Section 8  Exposure Controls / Protective Equipment

Hand protection

: Protective gloves.

Skin Protection

: Protective clothing.

Eye Protection

: Safety glasses. Ensure eye wash station is available.

Respiratory protection

: Respiratory protective device with particle 

fi

 lter.

Engineering measures

: Ensure there is adequate ventilation or dust 

mask.

 

Section 9  Physical and Chemical Properties

State

: Powder      

Solubility in water

: Soluble      

Odor

: Unpleasant

Color

: Off-white    

Melting point/range°C

: >400   

pH

: 5.3 (5% solution)

Section 10 Stability and Reactivity

Stability

: Stable under normal conditions.

Conditions to avoid

: Heat.

Materials to avoid

: Oxidising agents and acids.

Haz. decomp. products

: In combustion emits toxic fumes.

Section 11 Toxicological Information

Engineering Measures

: EZ Open Reducer Powder Pillow For Total Iron 

Test

Respiratory protection

: Refer to section 4 of MSDS for routes of 

exposure and corresponding symptoms.

Section 12 Ecological Information

Ecotoxicity operations

: EZ Open Reducer Powder Pillow For Total Iron 

Test

Mobility

: Soluble in water.

Persistence and degradability

: No data available.

Bioaccumulative potential

: No data available.

Other adverse effects

: Harmful to aquatic organisms.

Section 13 Disposal Considerations

Disposal operations

: Dissolve or mix the material with a combustible 

solvent and burn in a chemical incinerator equipped with an afterburner 

and scrubber. Observe all federal, state and local regulations.

Disposal of packaging

: Burn in a chemical incinerator equipped with 

afterburners and scrubbers.

NB

: The user’s attention is drawn to the possible existence of regional or 

national regulations regarding disposal.

Section 14 Transportation Information

UN no: - 

 

Shipping name: “Not subject to ADR”

ADR / RID   

IMDG / IMO 

IATA / ICAO

UN no: - 

 

UN no: - 

 

UN no: -

Содержание Well EZ

Страница 1: ...ADVANCED PHOTOMETER SYSTEM Well DIGITAL ACCURACY FOR RELIABLE WATER CARE QUICK START GUIDE...

Страница 2: ...T EZ PHOTOMETER Thank you for your Well eXact EZ purchase This guide will quickly walk you through the technical details of your new photometer After initial set up test procedures and tips you will b...

Страница 3: ...sure not to over tighten SAMPLE CELL 4 ML Built in plastic 4mL cell for collecting your water sample LCD DISPLAY Displays results and test name LIGHT SOURCE Uses 525nm wavelength and 11mm path length...

Страница 4: ...ith the water sample to be tested and FILL to the top to begin test 2 In bright light situations use cell cover for zeroing and reading TIP FILL DIP READ 3 SELECT TEST Press and re press the button un...

Страница 5: ...sult is automatically stored in the PH1 menu After testing is complete rinse the sample cell immediately 7 DIP STRIP AND PRESS READ Press to initiate a 20 second countdown and simultaneously DIP the e...

Страница 6: ...econds Ignore result displayed Clean cell with Distilled Vinegar 5 or 0 1N HCl before filling the meter with the sample to be tested If running multiple tests in a row using the same water sample the...

Страница 7: ...AD Press to initiate a 20 second countdown and simultaneously DIP the eXact Strip by submerging all pads in the sample then use a gentle constant back and forth motion 2 strokes per second until the t...

Страница 8: ...the water sample to be tested and FILL to the top to begin test 2 3 SELECT TEST Press and re press the button until the display shows No3 ZERO METER Press and the LCD Display reads 0 00PPM indicating...

Страница 9: ...ored in the No3 menu After testing is complete rinse the sample cell immediately and clean with brush 7 DIP STRIP AND PRESS READ Press to initiate a 20 second countdown and simultaneously DIP the eXac...

Страница 10: ...ve the most accurate result TIP FILL CELL Rinse the cell 3 times with the water sample to be tested and FILL to the top to begin test 2 ZERO METER Press and the LCD Display reads 0PPM indicating the m...

Страница 11: ...sample cell immediately 7 DIP STRIP AND PRESS READ Press to initiate a 20 second countdown and simultaneously DIP the eXact Strip by submerging all pads in the sample then use a gentle constant back a...

Страница 12: ...water sample to be tested and FILL to the top to begin test 2 1 POWER ON PHOTOMETER Press the button to power on the Well eXact EZ 3 SELECT TEST Press and re press the button until the display shows T...

Страница 13: ...ys 1 Remove and discard the strip 6 READ RESULTS READ result displayed as Total Hardness This result is automatically stored in the TH5 menu After testing is complete rinse the sample cell immediately...

Страница 14: ...iceably smaller or larger in width than the normal strips in the bottle These should be discarded Using these strips may give unreliable results Meter is not compatible for use with powder pillows tab...

Страница 15: ...t in the Well eXact EZ we offer an industry leading 2 year warranty We built the Well eXact EZ to be easy accurate and environmentally friendly We have achieved this by utilizing our patented eXact St...

Страница 16: ...faulty or otherwise defective contact ITS by phone 1 803 329 9712 Ext 0 or email its sensafe com to describe the problem and obtain a return authorization form before returning the photometer to ITS D...

Страница 17: ...pain may occur There may be vomiting Inhalation Absorption through the lungs can occur causing symptoms similar to those of ingestion Section 4 First Aid Measures Action Skin Contact Wash immediately...

Страница 18: ...ns Conditions to avoid Heat Materials to avoid Oxidising agents and acids Haz decomp products In combustion emits toxic fumes Section 11 Toxicological Information Engineering Measures EZ Open Reducer...

Страница 19: ...latory information given above only indicates the principal regulations specifically applicable to the product described in the material safety data sheet The user s attention is drawn to the possible...

Страница 20: ...up to date product information SENSAFE ITSSENSAFE Industrial Test Systems Inc 1875 Langston Street Rock Hill SC 29730 1 800 861 9712 Inside the U S A 1 803 329 9712 Outside the U S A Fax 1 803 329 974...

Отзывы: