28

©

2016, Industrial Test Systems, Inc. Printed in USA

† 

Value provided represents best possible accuracy under laboratory conditions, but may vary throughout the detection 

range. For a complete list of accuracies throughout all ranges, please visit 

sensafe.com/photometers/pool-exact-ez/

.  

1

 Performance veri

fi

 ed with various salt systems and water samples with optimal water  temperature at 10-40

˚

C / 50-104

˚

F. 

Optimal water temperature for Phosphate test is 15-40

˚

C / 59-104

˚

F. 

For detailed instructions on using this product, contact us (see below) or visit 

sensafe.com/photometers/pool-exact-ez/

.

Requires the use of 2 strips if reading is above 6 ppm.

Combined Chlorine DPD-3 Test requires Free Chlorine DPD-1 (486637) to be run 

fi

 rst. 

For resellers and distributors - products sold in case quantities (12 units per case).

PATENT INFORMATION 

US Patent #7,333,194; Euro Pat No. 1 725 864 DE FR UK; South Africa Pat No 2007/0628 
by Industrial Test Systems, Inc., 1875 Langston Street, Rock Hill, SC USA.
EXACT

®

 is a registered trademark of Industrial Test Systems, Inc. Rock Hill, SC USA.

EXACT

®

 MICRO TESTS & REAGENTS

PARAMETER / TEST

 

1

PART #

RANGE 

ppm

% BEST 

ACCURACY

 

# OF

TESTS

Alkalinity, Total

486641

10 – 200

10

100

Alkalinity, Total Range Extender 

2

486665

Each strip adds 130 ppm

100

Chloride (Salt)

486757

80 – 6700

5

25

Chlorine, Free (DPD–1) 

3

486637

0.01 – 12.0

5

100

Chlorine, Combined (DPD–3) 

4

486638

0.01 – 12.0

5

100

Copper

486632

0.06 – 9

2

50

Cyanuric Acid

481652-II

3 – 110

12

60

Hardness, Calcium

486629

3 – 700

5

50

pH

486639-II

6.4 – 8.4

0.2 pH

100

Phosphate

486814

0.02 – 4

8

50

EXACT REFILL BOX

PART #

PARAMETER / TESTS

Pool Re

fi

 ll Box

486211

Total Alkalinity, pH, Free Chlorine, 

Combined Chlorine, Calcium 

Hardness, Cyanuric Acid

R072016-PEZQG

Visit us online:

 

sensafe.com/photometers/pool-exact-ez/

for up–to–date product information.

SENSAFE

ITSSENSAFE

 Industrial Test Systems, Inc.
1875 Langston Street
Rock Hill, SC 29730 
1–800–861–9712—Inside the U.S.A.
1–803–329–9712—Outside the U.S.A.
Fax:1–803–329–9743
Email: [email protected]
WWW.SENSAFE.COM

ITS EUROPE, LTD
The UK Centre for Homeland Security
Building 7, Chilmark
Salisbury, Wiltshire, SP3 5DU, UK
Phone: +44 (0)1722 717911
Fax: +44 (0) 1722 717941
Email: [email protected]
WWW.ITSEUROPE.CO.UK

MANUFACTURED BY

Pool

ADVANCED PHOTOMETER SYSTEM

Содержание Pool EZ

Страница 1: ...1 Sensafe com QUICK START GUIDE Pool ADVANCED PHOTOMETER SYSTEM DIGITAL ACCURACY FOR BETTER POOL CARE...

Страница 2: ...inity Calcium Hardness Phosphate Chloride and Copper WHAT YOU WILL NEED TO GET STARTED Four 4 AAA batteries 4 Phillips head screwdriver Note This system has been calibrated for use with only our eXact...

Страница 3: ...meter on and creates a baseline for your water testing CELL COVER Covers the cell for mixing and bright light situations Protected against the effects of immersion in water to depth between 15cm and 1...

Страница 4: ...R Press and the LCD Display reads 0PPM indicating the meter is ready for testing 4 FILL DIP READ In bright light situations use cell cover for zeroing and reading TIP FILL CELL Rinse the cell 3 times...

Страница 5: ...initiate a 20 second countdown and simultaneously DIP the eXact Strip by submerging all pads in the sample then use a gentle constant back and forth motion 2 strokes per second until the timer display...

Страница 6: ...Pool eXact EZ 3 SELECT TEST Press and re press the button until the display shows PH2 ZERO METER Press and the LCD Display reads 0 0PH indicating the meter is ready for testing 4 In bright light situ...

Страница 7: ...result is automatically stored in the PH2 menu After testing is complete rinse the sample cell immediately 7 DIP STRIP AND PRESS READ Press to initiate a 20 second countdown and simultaneously DIP th...

Страница 8: ...ows CL3 ZERO METER Press and the LCD Display reads 0 00PPM indicating the meter is ready for testing 4 In bright light situations use cell cover for zeroing and reading TIP Use the included cleaning b...

Страница 9: ...nstant back and forth motion 2 strokes per second until the timer displays 1 Remove and discard the strip 6 READ RESULTS READ result displayed as Free Chlorine for result as Bromine multply value by 2...

Страница 10: ...dure is a continuation from Free Chlorine Test Method on previous pages DO NOT DISCARD SAMPLE FROM FREE CHLORINE TEST REMOVE STRIP Remove one eXact Strip Micro CL DPD 3 Combined Chlorine and set in a...

Страница 11: ...lorine reaction at all levels Chlorine Dioxide ClO2 Color similar to free chlorine reaction at all levels Copper Cu 2 Color development is reduced above 10 ppm mg L Iodine I2 Color similar to free chl...

Страница 12: ...g the meter is ready for testing 4 In bright light situations use cell cover for zeroing and reading TIP Clean CELL with 0 1N HCl Distilled Vinegar 5 or Muriatic Acid before filling the meter with the...

Страница 13: ...IP the eXact Strip by submerging all pads in the sample then use a gentle constant back and forth motion 2 strokes per second until the timer displays 1 Remove and discard the strip The display will a...

Страница 14: ...R Press and the LCD Display reads 0PPM indicating the meter is ready for testing 4 FILL DIP READ In bright light situations use cell cover for zeroing and reading TIP FILL CELL Rinse the cell 3 times...

Страница 15: ...s CaCO3 This result is automatically stored in the CA5 menu After testing is complete rinse the sample cell immediately 7 FILL DIP READ DIP STRIP AND PRESS READ Press to initiate a 20 second countdown...

Страница 16: ...ZERO METER Place cell cover on sample cell before zeroing Press and the LCD Display reads 0PPM indicating the meter is ready for testing 4 FILL DIP READ FILL CELL Rinse the cell 3 times with the wate...

Страница 17: ...READ result displayed as Cyanuric Acid This result is automatically stored in the CY6 menu After testing is complete rinse the sample cell immediately 7 FILL DIP READ CAP PRESS READ Place the cell cov...

Страница 18: ...ERO METER Press and the LCD Display reads 0 00PPM indicating the meter is ready for testing 4 In bright light situations use cell cover for zeroing and reading TIP FILL CELL Rinse the cell 3 times wit...

Страница 19: ...the eXact Strip by submerging all pads in the sample then use a gentle constant back and forth motion 2 strokes per second until the timer displays 1 Remove and discard the strip The display will aut...

Страница 20: ...the 2 0mL line very precisely plunger ring should line up at the 2 0mL line and little or no air bubble should be present 3 Add the syringe content 2 0mL salt water sample to a clean 50mL graduated c...

Страница 21: ...and the LCD Display reads 0 00PPM indicating the meter is ready for testing 4 In bright light situations use cell cover for zeroing and reading TIP FILL CELL Rinse the cell 3 times with the water sam...

Страница 22: ...ubmerging all pads in the sample then use a gentle constant back and forth motion 2 strokes per second until the timer displays 1 Remove and discard the strip 6 READ RESULTS READ result displayed as C...

Страница 23: ...e Test immediately after filling the cell with the water sample To obtain optimal accuracy when testing outdoors sunlight use the cell cover when zeroing and reading the sample Due to the strip slitti...

Страница 24: ...technical information and how to videos For additional technical support call 803 329 9712 Industrial Test Systems Inc 1875 Langston Street Rock Hill SC 29730 800 861 9712 or 803 329 9712 its sensafe...

Страница 25: ...email its sensafe com to describe the problem and obtain a return authorization form before returning the photometer to ITS Damage caused by improper packing of the photometer for return shipment to I...

Страница 26: ...hlorine and the eXact Strip Micro CL DPD 3 for Combined Chlorine and the eXact Strip Micro CL DPD 4 for Total Chlorine meet your reportable testing requirements because the eXact Strip Micro strips de...

Страница 27: ...27 Sensafe com NOTES...

Страница 28: ...rial Test Systems Inc Rock Hill SC USA EXACT MICRO TESTS REAGENTS PARAMETER TEST 1 PART RANGE ppm BEST ACCURACY OF TESTS Alkalinity Total 486641 10 200 10 100 Alkalinity Total Range Extender 2 486665...

Отзывы: