UFS8000
Components
34
6.8. Pressure meter
The pressure meters equipped with a 0(4)-20mA output can be connected to the control panel.
It is possible to specify thresholds for the upper and lower limits, both with a programmable time delay.
It is also possible to specify whether the installation should be shut down in case of either positive or
negative crossing of the specified values.
If the thresholds are activated, it is possible to send an alarm message when, for instance, the upper
threshold is exceeded (this can be either through a relay or with an e-mail (only possible with
UFS8x1x-xxxx)).
The properties of the pressure meters are only visible if the control panel is equipped with prints with
0-20mA inputs (ca-fl-pr-3an).
6.8.1. Pressure Feed 1
This meter indicates the pressure in the feed pipe.
The way of editing flow measurements is described in § 6.8.7 “Pressure meter settings” on page 35.
6.8.2. Pressure Feed 2
This meter indicates the pressure in the feed pipe.
The way of editing flow measurements is described in § 6.8.7 “Pressure meter settings” on page 35.
With the inventory, the screen number needs to be increased by 10 each time.
With programming the screen number needs to be increase by 20 each time.
6.8.3. Pressure Backwash
This meter indicates the pressure in the backwash pipe.
The way of editing flow measurements is described in § 6.8.7 “Pressure meter settings” on page 35.
With the inventory, the screen number needs to be increased by 20 each time.
With programming the screen number needs to be increase by 40 each time.
6.8.4. Pressure Air
This meter indicates the pressure in the air pipe.
The way of editing flow measurements is described in § 6.8.7 “Pressure meter settings” on page 35.
With the inventory, the screen number needs to be increased by 30 each time.
With programming the screen number needs to be increase by 60 each time.
6.8.5. Pressure Concentrate
This meter indicates the pressure in the concentrate pipe.
The way of editing flow measurements is described in § 6.8.7 “Pressure meter settings” on page 35.
With the inventory, the screen number needs to be increased by 40 each time.
With programming the screen number needs to be increase by 80 each time.
6.8.6. Pressure Permeate
This meter indicates the pressure in the permeate pipe.
The way of editing flow measurements is described in § 6.8.7 “Pressure meter settings” on page 35.
With the inventory, the screen number needs to be increased by 50 each time.
With programming the screen number needs to be increase by 100 each time.
Содержание UFS8000
Страница 1: ...Controller for ultra filtration plants Operating manual Software version 1 06 UFS8000 ...
Страница 7: ...40 Warranty conditions 122 ...
Страница 11: ...UFS8000 Picture of front side 4 2 Picture of front side 1 LCD display touch panel ...
Страница 115: ...UFS8000 Overview menu 108 30 Overview menu ...
Страница 117: ...UFS8000 Terminal Block 110 32 Terminal block connection 32 1 Schematics ...
Страница 118: ...UFS8000 Terminal Block 111 ...