OS3030
Installation instructions
"Standby stop" phase display during start-up,
activating the "standby stop" phase
39
Installation instructions / Start-up
Install the device at eye level and ensure that it is very accessible for the operator.
Do not install it under dripping pipes. Possibly attach a protective guard.
Slide the panel-mounted version into the control panel cut-out, 186 X 138, and secure it in place
using the enclosed tightening clips.
Connect to the power supply. Comply with regulations issued by local power supply utilities and
as well as with any factory standards which may apply.
Pay particular attention to ensuring that the safety-earth terminal is in perfect working order.
Keep all low-voltage control cables (terminals 11
22, i.e. connections for FU, EM, IN1, IN2, IN3
and CC) separate from mains power cables.
Fit suppressers to coils for contactors which are installed directly beside the system.
WARNING! The panel-mounted version is supplied without mains switches. Install an interrupting
device in the control cabinet, for example.
Switch on the device and carry out the basic programming using these instructions and the tech-
nical information provided by the manufacturer of the system.
Start up the system in accordance with the manu
facturers instructions.
Measure the conductivity
of the permeate using the conductivity meter and compare this with the value shown on the LCD.
ATTENTION
: Some external relays, magnetic switches, magnetic valves, etc. can cause
undesirable interference pulses when switching off. For this reason it is recommended to provide
the components mentioned, in advance, with a RC-network.
Inquire at the supplier of the components mentioned for the correct type of RC-network.
"STANDBY STOP" phase display during start-up
During initial start-up, the LCD reads:
The high-pressure pump and the valves are not activated in this position.
Possible actions:
1. Programming the basic settings
2. Calling up the Info displays
3. Switching the "MAINTENANCE" position on and off
4. Starting a production cycle
5. Stopping a production cycle or starting a rinse cycle
6. Cancelling the fault or signal alarm relay
Once you have pressed "ON" to start production or "OFF" to stop production, the "STANDBY STOP"
function is cancelled. The normal start procedure takes place the next time it is switched on at the
mains. It generally starts with a rinse cycle.
Activating the "STANDBY STOP" phase
The "STANDBY STOP" can be re-activated:
1. Press "ON" and switch it on at the mains.
2. After installing a new version of the software.
3. After a power failure if you have selected "Yes" for the Stop Manual Start option in programming
step 5.14.
Application: For technical reasons, the system does not restart automatically after a power failure.