Design and function
Shielding gas supply (shielding gas cylinder for welding machine)
32
099-004934-EW501
13.06.2013
5.8.1
Connection
Figure 5-5
Item Symbol
Description
0
1
Pressure regulator
2
Shielding gas cylinder
3
Output side of the pressure regulator
4
Cylinder valve
• Place the shielding gas cylinder into the relevant cylinder bracket.
• Secure the shielding gas cylinder using a securing chain.
• Tighten the pressure regulator screw connection on the gas bottle valve to be gas-tight.
• Screw the gas hose connection nipple (intermediate tube package) onto the output side of the
pressure regulator.