Technical data
Wega 501, 601 FDW
099-004934-EW501
13.06.2013
43
8.4
Wega 501, 601 FDW
501 DW
601 DW
Switching steps
36 (3 x 12)
Setting range for welding current
50 A to 500 A
50 A to 600 A
Setting range for welding voltage
16.5 V
–39.0 V
16.5 V
–44.0 V
Duty cycle at 40 °C ambient temperature
45%
-
600 A
60%
500 A
-
100%
400 A
450 A
Duty cycle at 25 °C ambient temperature
60%
-
600 A
70%
500 A
-
100%
400 A
450 A
Open circuit voltage
16.5 V to 49.5 V
16.5 V to 57.5 V
Mains connection lead
H07RN-F4G6
Mains voltage (tolerances)
3 x 400 V (+/- 15%)
Frequency
50/60 Hz
Mains fuse
(safety fuse, slow-blow)
3 x 32 A
Max. connected load
27.5 kVA
36.7 kVA
Rec. generator rating
32 kVA
50 kVA
Workpiece lead
95 mm
2
cos
0.95
Tank capacity (max.)
7 l
Flow rate (max.)
5l/min
Cooling capacity at 1 l/min
1200 W
Outlet pressure (max.)
3.5 bar
Weight
213 kg
236 kg
Dimensions L x W x H in mm
960 x 560 x 1010
Insulation class/protection classification
H/IP 23
Ambient temperature*
-25
C to +40
C
Machine/torch cooling
Fan/water
EMC class
A
Constructed to standard
IEC 60974-1, -2, -10
/
NOTE
*
Ambient temperature depends on coolant!
Observe the coolant temperature range for the welding torch cooling!
Содержание Wega 401 FDG
Страница 18: ...Machine description quick overview Wega 401 18 099 004934 EW501 13 06 2013 4 1 2 Rear view Figure 4 2...
Страница 22: ...Machine description quick overview Wega 501 601 22 099 004934 EW501 13 06 2013 4 2 2 Rear view Figure 4 4...
Страница 47: ...Appendix A Setting instructions 099 004934 EW501 13 06 2013 47 Figure 10 2...
Страница 48: ...Appendix A Setting instructions 48 099 004934 EW501 13 06 2013 Figure 10 3...
Страница 49: ...Appendix B Overview of EWM branches 099 004934 EW501 13 06 2013 49 11 Appendix B 11 1 Overview of EWM branches...