Design and function
Intermediate hose package connection
099-004934-EW501
13.06.2013
29
5.7
Intermediate hose package connection
5.7.1
Wega 401
Figure 5-3
Item Symbol
Description
0
1
Wire feed unit
2
Intermediate hose package
3
Intermediate hose package strain relief
4
7-pole connection socket
Wire feed unit control lead
5
Earth cable connecting (PE)
Connection of green-yellow earth cable from the intermediate tube package
6
Connector plug, welding current "+"
Welding current connection on wire feed unit
7
Quick connect coupling (blue)
coolant supply
8
Quick connect coupling (red)
coolant return
• Insert the end of the hose package through the strain relief of the hose package and lock by turning to
the right.
• Insert the plug on the welding current lead into the welding current connection socket "+" and lock.
• Insert cable plug on the control lead into the 7-pole connection socket and secure with crown nut (the
plug can only be inserted into the connection socket in one position).
• Screw the eyelet of the earth lead on to the connecting nipple of the earth lead.
If fitted:
• Lock connecting nipples of the cooling water tubes into the corresponding quick connect couplings:
Return line red to quick connect coupling, red (coolant return) and
supply line blue to quick connect coupling, blue (coolant supply).
Содержание Wega 401 FDG
Страница 18: ...Machine description quick overview Wega 401 18 099 004934 EW501 13 06 2013 4 1 2 Rear view Figure 4 2...
Страница 22: ...Machine description quick overview Wega 501 601 22 099 004934 EW501 13 06 2013 4 2 2 Rear view Figure 4 4...
Страница 47: ...Appendix A Setting instructions 099 004934 EW501 13 06 2013 47 Figure 10 2...
Страница 48: ...Appendix A Setting instructions 48 099 004934 EW501 13 06 2013 Figure 10 3...
Страница 49: ...Appendix B Overview of EWM branches 099 004934 EW501 13 06 2013 49 11 Appendix B 11 1 Overview of EWM branches...