Design and function
Adapting the Euro torch connection on the device
099-600010-EW501
27.02.2018
11
5.2
Adapting the Euro torch connection on the device
On delivery, the Euro torch connector is fitted with a capillary tube for welding torches with steel
liners!
5.2.1
Liner
• Push forward the capillary tube on the wire feed side in the direction of the Euro torch connector and
remove it there.
• Insert the guide tube from the Euro torch connection.
• Carefully insert the welding torch connector with as yet too long a liner into the Euro torch connector
and secure with a crown nut.
• Cut off the liner using a special cutter or sharp knife just before the wire feed roller, making sure not to
pinch it.
• Loosen the welding torch connector and remove.
• Cleanly trim the separated end of the liner!
5.2.2
Replace steel liner
• Check that the capillary tube is correctly positioned in relation to the central connector!
• Insert the central plug for the welding torch into the central connector and screw together with crown
nut.