Design and function
MMA welding
099-004854-EW501
19.02.2014
69
5.10
MMA welding
CAUTION
Risk of being crushed or burnt.
When replacing spent or new stick electrodes
• Switch off machine at the main switch
• Wear appropriate safety gloves
• Use insulated tongs to remove spent stick electrodes or to move welded workpieces and
• Always put the electrode holder down on an insulated surface.
Shielding gas connection!
During MMA welding open circuit voltage is applied at the shielding gas connection
(G¼" connecting nipple).
• Place yellow insulating cap on the G¼" connection nipple (protects against electrical
voltage and dirt).
5.10.1
Connecting the electrode holder and workpiece lead
CAUTION
Shielding gas connection!
During MMA welding open circuit voltage is applied at the shielding gas connection
(G¼" connecting nipple).
• Place yellow insulating cap on the G¼" connection nipple (protects against electrical
voltage and dirt).
Figure 5-31
Содержание Tetrix 350
Страница 7: ...Contents Notes on the use of these operating instructions 099 004854 EW501 19 02 2014 7...
Страница 20: ...Machine description Rear view 20 099 004854 EW501 19 02 2014 4 2 Rear view Figure 4 2...
Страница 115: ...Appendix B Overview of EWM branches 099 004854 EW501 19 02 2014 115 11 Appendix B 11 1 Overview of EWM branches...