Design and function
TIG Synergic operating principle
099-004854-EW501
19.02.2014
59
5.9.12
Pulses, function sequences
NOTE
The function sequences in pulses basically behave in the same way as in standard
welding, but during the main current phase there is a continual switching back and forth
between the pulse and pause currents at the relevant times.
The pulse function can also be deactivated if necessary during the upslope and
downslope phases (see chapter "Advanced settings").
5.9.12.1
TIG pulses
– non-latched operation
Figure 5-21
5.9.12.2
TIG pulses - latched operation
Figure 5-22
Содержание Tetrix 350
Страница 7: ...Contents Notes on the use of these operating instructions 099 004854 EW501 19 02 2014 7...
Страница 20: ...Machine description Rear view 20 099 004854 EW501 19 02 2014 4 2 Rear view Figure 4 2...
Страница 115: ...Appendix B Overview of EWM branches 099 004854 EW501 19 02 2014 115 11 Appendix B 11 1 Overview of EWM branches...