Design and function
MMA welding
099-000159-EW501
16.08.2016
59
5.11 MMA
welding
CAUTION
Risk of being crushed or burnt.
When replacing spent or new stick electrodes
• Switch off machine at the main switch
• Wear appropriate safety gloves
• Use insulated tongs to remove spent stick electrodes or to move welded workpieces and
• Always put the electrode holder down on an insulated surface.
Shielding gas connection!
During MMA welding open circuit voltage is applied at the shielding gas connection
(G¼" connecting nipple).
• Place yellow insulating cap on the G¼" connection nipple (protects against electrical
voltage and dirt).
5.11.1 Connecting the electrode holder and workpiece lead
Polarity depends on the instructions from the electrode manufacturer given on the electrode
packaging.
Figure 5-45
Item Symbol Description
0
1
Electrode holder
2
Connection socket, “-” welding current
Workpiece lead or electrode holder connection
3
Workpiece
4
Connection socket for "+" welding current
Electrode holder or workpiece lead connection
5
Connecting nipple G¼, shielding gas connection
• Fit yellow protective cap onto G¼" connecting nipple.
• Insert cable plug of the electrode holder into either the "+" or "-" welding current connection socket and
lock by turning to the right.
• Insert cable plug of the workpiece lead into either the "+" or "-" welding current connection socket and
lock by turning to the right.
Содержание Tetrix 230 AC/DC Comfort 8P TM
Страница 63: ...Design and function MMA welding 099 000159 EW501 16 08 2016 63 EXIT 3s 2s Figure 5 51 ...
Страница 67: ...Design and function Machine configuration menu 099 000159 EW501 16 08 2016 67 l 0 3s 3s 3s Figure 5 53 ...
Страница 82: ...Appendix B Overview of EWM branches 82 099 000159 EW501 16 08 2016 11 Appendix B 11 1 Overview of EWM branches ...