Design and function
Access control
66
099-000159-EW501
16.08.2016
5.13.2 Power-saving mode (Standby)
You can activate the power-saving mode by either pressing the push-button
> see 4.3 chapter
for a
prolonged time or by setting a parameter in the machine configuration menu (time-controlled power-
saving mode)
> see 5.15 chapter
.
When power-saving mode is activated, the machine displays show the horizontal digit in the
centre of the display only.
Pressing any operating element (e.g. tapping the torch trigger) deactivates power-saving mode and the
machine is ready for welding again.
5.14 Access
control
The machine control can be locked to secure it against unauthorised or unintentional adjustment. The
access block has the following effect:
• The parameters and their settings in the machine configuration menu, Expert menu and operation
sequence can only be viewed but not changed.
• Welding procedure and welding current polarity cannot be changed.
The parameters for the access block are configured in the machine configuration
menu
> see 5.15 chapter
.
Enabling the access block
• Assign the access code for the access block: Select parameter
and select a number code (0–
999).
• Enable access block: Set parameter to function
.
Disabling the access block
• Enter the access code for the access block: Select parameter
and enter the number code (0–999).
• Disable access block: Set parameter to
.
The only way to disable the access block is to enter the selected number code.
Changing the access block
• Enter the access code for the access block: Select parameter
and enter the previously selected
number code (0–999).
• Change the access block: Set parameter
and assign a new code (0–999).
5.15 Machine configuration menu
Basic machine settings are defined in the machine configuration menu.
5.15.1 Selecting,
changing and saving parameters
ENTER (enter the menu)
• Switch off machine at the main switch
• Press and hold the "welding parameters" button and switch the machine on again at the same
time.
NAVIGATION (navigating in the menu)
• Parameters are selected by pressing the "welding parameters" button.
• Set or change the parameters by turning the "welding parameter setting" rotary dial.
EXIT (leave the menu)
• Select the "Elt" menu item.
• Press the "welding parameters" button (settings will be applied, machine changes to the
ready-to-operate status).
Содержание Tetrix 230 AC/DC Comfort 8P TM
Страница 63: ...Design and function MMA welding 099 000159 EW501 16 08 2016 63 EXIT 3s 2s Figure 5 51 ...
Страница 67: ...Design and function Machine configuration menu 099 000159 EW501 16 08 2016 67 l 0 3s 3s 3s Figure 5 53 ...
Страница 82: ...Appendix B Overview of EWM branches 82 099 000159 EW501 16 08 2016 11 Appendix B 11 1 Overview of EWM branches ...