Appendix A
Parameter overview – setting information
80
099-000159-EW501
16.08.2016
10 Appendix
A
10.1 Parameter overview – setting information
10.1.1 TIG
welding
Parameter
TIG/plasma
Display Setting
range
Comment
Code
Unit
Standa
rd
Min.
Max.
Main current
A
3 -
230
Gas pre-flow time
s 0,1 0,1 -
5,0
Ignition current AMP%
%
20
1
-
200
% of main current AMP
Up-slope time
s 0,1 0,0 -
20,0
Pulse time
s 0,1 0,01
-
9,99
Secondary current AMP%
%
50
1
200
% of main current AMP
Pulse pause time
s 0,1 0,01
-
9,99
Down-slope time “ ”
s 0,1 0,0 -
20,0
Down-slope time “
”
s 5,0 0,0 -
20,0
End current AMP%
%
20
1
-
200
% of main current AMP
Gas post-flow time
s 8
0,1 -
20,0
Electrode diameter
mm 1,6 1,0 -
4,0
spotArc time
s 2,0 0,01
-
20,0
AC balance (JOB 0)
%
-30 -
+30 Rotary
knob
AC balance (JOB 1-7)
% 0
-30 -
+30
Pulse balance
% 50
1 -
99 Pulsing,
metallurgical
Pulse frequency
Hz 50
50 - 15000 Pulsing,
metallurgical
AC frequency (JOB 0)
Hz -
50 -
200
AC frequency (JOB 1-7)
Hz 50
50 -
200
activArc
50 0 -
100
Содержание Tetrix 230 AC/DC Comfort 8P TM
Страница 63: ...Design and function MMA welding 099 000159 EW501 16 08 2016 63 EXIT 3s 2s Figure 5 51 ...
Страница 67: ...Design and function Machine configuration menu 099 000159 EW501 16 08 2016 67 l 0 3s 3s 3s Figure 5 53 ...
Страница 82: ...Appendix B Overview of EWM branches 82 099 000159 EW501 16 08 2016 11 Appendix B 11 1 Overview of EWM branches ...