Rectifying faults
Error messages (power source)
50
099-005649-EW501
19.11.2020
Category
Error
Possible cause
Remedy
a) b) c)
54
VRD error
[2]
Open circuit voltage reduction
error
if necessary, disconnect ex-
ternal machine from the
welding circuit; inform Service
55
WF excess cur-
rent
Overcurrent detection on wire
feeder
Do not place the liner in tight
radii; check wire core for
smooth movement
56
Mains phase
failure
One phase of the mains voltage
has failed
Check mains connection,
mains plug and mains fuses
57
Slave tacho er-
ror
Wire feeder fault (slave drive)
Check connectors, cables,
connections
Permanent overload of the wire
drive (slave drive)
Do not place the liner in tight
radii; check wire core for
smooth movement
58
Short circuit
Check welding circuit for short
circuit
Check welding circuit; isolate
welding torch before deposi-
ting
59
Incompatible
machine
A machine connected to the
system is not compatible
Please disconnect the incom-
patible machine from the sys-
tem
60
Incompatible
software
A machine's software is not
compatible.
Inform Service
61
Welding moni-
tor
The actual value of a welding
parameter is outside the spe-
cified tolerance field
Observe tolerance fields; ad-
just welding parameters
62
System compo-
nent
[3]
System component not found
Inform Service
[1]
factory setting
[2]
option
[3]
only machine series Titan XQ, Phoenix XQ, Taurus XQ