Design and function
Special parameters (advanced settings)
099-005431-EW501
04.02.2016
101
Predefined absolute value for relative programs (P21)
Start program (P
START
), down-slope program (P
B
) and end program (P
END
) can be set relative to the main
program (P
A
) or in an absolute manner, as desired.
Function active (P21 = 1)
• Absolute parameter setting
Function inactive (P21 = 0)
• Relative parameter setting (ex factory)
Electronic gas flow control, type (P22)
Active only in machines with integrated gas flow control (option ex works).
Adjustment may only be carried out by authorised service personnel (basic setting = 1).
Program settings for relative programs (P23)
The start, down-slope and end program relative programs can be set individually or combined for the P0-
P15 operating points. When choosing the combined setting, in contrast to the individual setting, the
parameter values are saved in the JOB With the individual setting, the parameter values are identical for
all JOBs (except for special JOBs SP1,SP2 and SP3).
Correction or nominal voltage display (P24)
When setting the arc correction using the right-hand rotary knob the display will either show the correction
v- 9.9 V (ex works) or the absolute nominal voltage.
Содержание Taurus 351-401 Synergic S HP MM FKG
Страница 6: ...Contents Notes on the use of these operating instructions 6 099 005431 EW501 04 02 2016...
Страница 20: ...Machine description quick overview Rear view 20 099 005431 EW501 04 02 2016 4 2 Rear view Figure 4 2...
Страница 22: ...Machine description quick overview Inside view 22 099 005431 EW501 04 02 2016 4 3 Inside view Figure 4 3...
Страница 122: ...Appendix A JOB List 122 099 005431 EW501 04 02 2016 11 Appendix A 11 1 JOB List Figure 11 1...
Страница 123: ...Appendix B Overview of EWM branches 099 005431 EW501 04 02 2016 123 12 Appendix B 12 1 Overview of EWM branches...