Design and function
MIG/MAG welding
099-005431-EW501
04.02.2016
65
5.8.7.2 MIG/MAG
overview of parameters
Figure 5-30
Basic Parameters
Item
Meaning / Explanation
Setting Range
1
1
Gas pre-flow time
0.0s to 20.0s
2
2
P
START
Wire speed, relative
Arc length correction
1% to 200%
-9.9V to +9.9V
3
3
Duration
0.0s to 20.0s
4
4
Slope duration from P
START
to P
A
0.0s to 20.0s
5
5
P
A
Wire speed, absolute
0.1 m/min to 40 m/min
6
7
Duration (spot time and superpulse)
0.01s to 20.0s
7
8
P
B
Wire speed, relative
Arc length correction, relative
1% to 200%
-9.9V to +9.9V
8
9
Duration
0.01s to 20.0s
9
1
0
Slope duration from P
A
to P
END
0.0s to 20s
10 1
1
P
END
Wire speed, relative
Arc length correction
1% to 200%
-9.9V to +9.9V
11 1
2
Duration (superpulse)
0.0s to 20s
12 1
3
Gas post-flow time
0.0s to 20s
13 1
4
superPuls
On / Off
P
START
, P
B
, and P
END
are set as relative programs ex faxtory. They relate to percentages of the wire
feed value of the main program P
A
. These programs can also be set in an absolute manner, if
desired (see Setting of special parameter P21).
Содержание Taurus 351-401 Synergic S HP MM FKG
Страница 6: ...Contents Notes on the use of these operating instructions 6 099 005431 EW501 04 02 2016...
Страница 20: ...Machine description quick overview Rear view 20 099 005431 EW501 04 02 2016 4 2 Rear view Figure 4 2...
Страница 22: ...Machine description quick overview Inside view 22 099 005431 EW501 04 02 2016 4 3 Inside view Figure 4 3...
Страница 122: ...Appendix A JOB List 122 099 005431 EW501 04 02 2016 11 Appendix A 11 1 JOB List Figure 11 1...
Страница 123: ...Appendix B Overview of EWM branches 099 005431 EW501 04 02 2016 123 12 Appendix B 12 1 Overview of EWM branches...