Taurus 351 FKG
MIG/MAG
TIG
MMA
Setting range for welding current
5 A
–350 A
Setting range for welding voltage
14.3 V- 31.5 V
10.2 V
–24.0 V
20.2 V
–34.0 V
Duty cycle at 40 °C
100%
350 A
Load cycle
10 min (60% DC
6 min welding, 4 min pause)
Open circuit voltage
79 V
Mains voltage (tolerances)
3 x 400 V (-25% to +20%)
Frequency
50/60 Hz
Mains fuse (safety fuse, slow-blow)
3 x 25 A
Mains connection lead
H07RN-F4G6
Maximum connected load
13.9 kVA
10.9 kVA
15.0 kVA
Recommended generator rating
20.3 kVA
cos
/efficiency
0.99/90%
Insulation class/protection
classification
H/IP 23
Ambient temperature*
-25 °C to +40 °C
Machine/welding torch cooling
Fan/gas
Workpiece lead
70 mm²
Wire feed speed
0.5 m/min. to 24 m/min.
Standard roller installation
1.0 mm + 1.2 mm (for steel wire)
Wire feed type
4 rolls (37 mm)
Wire spool diameter
Standardized wire spools up to 300 mm
Welding torch connection
Euro torch connector
EMC class
A
Dimensions L x W x H in mm
1085 x 450 x 1003
Weight
110.0 kg
Constructed to standard
IEC 60974-1, -5, -10
/
Содержание Taurus 351-401 Synergic S HP MM FKG
Страница 6: ...Contents Notes on the use of these operating instructions 6 099 005431 EW501 04 02 2016...
Страница 20: ...Machine description quick overview Rear view 20 099 005431 EW501 04 02 2016 4 2 Rear view Figure 4 2...
Страница 22: ...Machine description quick overview Inside view 22 099 005431 EW501 04 02 2016 4 3 Inside view Figure 4 3...
Страница 122: ...Appendix A JOB List 122 099 005431 EW501 04 02 2016 11 Appendix A 11 1 JOB List Figure 11 1...
Страница 123: ...Appendix B Overview of EWM branches 099 005431 EW501 04 02 2016 123 12 Appendix B 12 1 Overview of EWM branches...