Welding procedure
Power-saving mode (Standby)
099-00T400-EW501
21.10.2016
65
4.4
Power-saving mode (Standby)
You can activate the power-saving mode by either pressing the push-button
> see 3 chapter
for a
prolonged time or by setting a parameter in the machine configuration menu (time-controlled power-
saving mode
)
> see 4.7 chapter
.
When power-saving mode is activated, the machine displays show the horizontal digit in the
centre of the display only.
Pressing any operating element (e.g. tapping the torch trigger) deactivates power-saving mode and the
machine is ready for welding again.
4.5
Access control
The machine control can be locked to secure it against unauthorised or unintentional adjustment. The
access block has the following effect:
• The parameters and their settings in the machine configuration menu, Expert menu and operation
sequence can only be viewed but not changed.
• Welding procedure and welding current polarity cannot be changed.
The parameters for setting the access block are configured in the machine configuration
menu
> see 4.7 chapter
.
Enabling access block
• Assign the access code for the access block: Select parameter
and select a number code (0
–
999).
• Enable access block: Set parameter
to access block enabled
.
The access block activation is indicated by the "Access block active" signal light
> see 3.1.1 chapter
.
Disabling access block
• Enter the access code for the access block: Select parameter
and enter the previously selected
number code (0
–999).
• Disable access block: Set parameter
to access block disabled
. The only way to disable the
access block is to enter the selected number code.
4.6
Voltage reducing device
The machine can be equipped with a VRD(Voltage-reducing device) to increase safety, particularly in
hazardous environments such as those in shipbuilding, pipe construction or mining (identified with name
prefix "VRD").
The VRD signal light comes on when the voltage reduction device is operating perfectly and the output
voltage is reduced to the value specified in the relevant technical standard..
4.7
Machine configuration menu
Basic machine settings are defined in the machine configuration menu.
4.7.1
Selecting, changing and saving parameters
ENTER (Enter the menu)
• Switch off the machine at the main switch.
• Press and hold the control button while switching the machine on again at the same time.
NAVIGATION (Navigate the menu)
• Parameters are selected by pressing the control button.
• Set or change the parameters by turning the control button.
EXIT (Exit the menu)
• Select menu item
.
• Press control button (settings will be applied, machine changes to the ready-to-operate
status).