Welding procedure
TIG welding
18
099-00T400-EW501
21.10.2016
4.1.3
Tungsten balling function
The tungsten balling function provides optimum tungsten balling, ensuring that the best ignition and
welding results are achieved during AC welding.
Optimum tungsten balling requires a sharpened electrode (about 15
–25°) and the set electrode diameter
on the machine control. The set electrode diameter affects the current for tungsten balling and,
consequently, also the ball size.
Press the tungsten balling push-button to activate the function. If required, this current can be adjusted on
an individual basis using the
parameter (+/- 30 A). The user presses the torch trigger and the function
is started by non-contact ignition (HF start). The balled end is formed and the function then ends.
Tungsten balling should be performed on a test component as surplus tungsten may be melted and this
may lead to impurities on the weld seam.
Balling
mm
inch
Figure 4-3