5
Steuerungsbeschreibung M100 / M110
5/3
5.3
Setting further welding parameters
Operating elements for setting the following welding parameters are in the welding machine or the
wire-feed unit (Fig. 5/2).
Fig. 5/2 Setting possibilities in the welding machine or the wire-feed unit
5.3.1
Wire Burn-back
Trimmer
Wire Burn-back
steplessly
adjustable:
0 - 250 ms
Setting Instructions:
If burn-back is set too high: the formation of large globes on
the end of the welding wire causes poor arc striking
performance or the wire is melted into the contact tip.
If burn-back is set too low: the welding wire gets stuck in the
weld-pool.
5.3.2
Gas after flow time
Trimmer
Gas after-flow
time
steplessly
adjustable:
0,2 - 10 sec.
The gas after flow is intended to ensure that the weld-pool
solidifies under a shielding gas atmosphere so no crater
porosity is caused.
5.3.3
Feeding in the welding wire
Button
arc-off wire
threading
The welding wire can be threaded through the hose-pack
without voltage and without gas flowing.
Содержание SATURN MIG 200
Страница 17: ...4 Description of the System components 4 1 4 1 System Summary...
Страница 20: ...4 Description of the System components 4 4 4 3 Controls 4 3 1 Control PROGRAM M201 Fig 4 3 Control PROGRAM M201...
Страница 54: ......
Страница 55: ...12 Ersatzteilliste Spare Parts List 12 1...
Страница 56: ...12 Ersatzteilliste Spare Parts List 12 2 Abb 12 1 Vorderseite front view Abb 12 2 R ckseite rear view...
Страница 58: ...12 Ersatzteilliste Spare Parts List 12 4 Abb 12 3 rechte Seite right side Abb 12 4 linke Seite left side...
Страница 65: ...14 Schaltpl ne Circuit diagrams 14 1 SATURN 250 300 M100...
Страница 66: ...14 Schaltpl ne Circuit diagrams 14 2 SATURN 250 300 M100 M110...
Страница 67: ...14 Schaltpl ne Circuit diagrams 14 3 SATURN 250 300 M200...
Страница 68: ...14 Schaltpl ne Circuit diagrams 14 4 SATURN 250 300 M200 M110...