5
Steuerungsbeschreibung M100 / M110
5/4
5.3.4
Creep start
Creep start
The wire creep feed-rate is a percentage of the preset
wire feed rate.
As standard this is factory set to 50%.
(e.g.: Wire-feed speed = 10m/min
≥
Creep speed =
5 m/min)
Advantage: The welding wire does not hit the workpiece at
full speed. A reliable, splatter free striking of the arc is made
possible.