Machine description – quick overview
Machine control – Operating elements
099-004968-EW501
13.09.2021
21
Item Symbol Description
0
8
Wire feed speed/welding parameter rotary knob
Infinite adjustment of the wire feed speed/welding parameters and corresponding va-
lues
9
Gas test push-button
> see 5.1.5.3 chapter
10
Wire inching push-button
For potential- and gas-free inching of the wire electrode through the hose package to
the welding torch.
4.3.2.1 Setting the operating point (welding output)
This control works according to the twin-knob operation principle. To set the operating point, only the wire
speed and the welding voltage need to be set according to the material and the electrode diameter.
Operating ele-
ment
Action
Result
Wire speed setting
Welding voltage setting
4.3.2.2 Setting the operating mode and runtime parameters
The parameters are pre-set in the control but can be adjusted individually.
If there is no user action within 5 seconds during the setting process, the control interrupts the
process and switches back to the standard display.
Operating ele-
ment
Action
Result
n x
Select operating mode:
---------- Non-latched
-------- Latched
------- Spots
------ Interval
n x
Select welding parameter:
------ Set gas post-flow time "GnS"
(0.0 s to 10.0 s)
------- Set wire burn-back time "drb" (-50% to 50%)
-- Spot/interval time "t1" (0.1 s to 5.0 s)
----- Interval/pause "t2" (0.1 s to 2.0 s)
The selected parameter is shown on the display
Set the parameter chosen
4.3.2.3 Setting the expert parameters
The parameters are pre-set in the control but can be adjusted individually.
If there is no user action within 5 seconds during the setting process, the control interrupts the
process and switches back to the standard display.
Operating ele-
ment
Action
Result
1 x
Select expert parameters.
The combination of button must be pressed within 3 seconds.