Design and function
MMA welding
34
099-002060-EW501
19.10.2015
5.7.5
Expert menu (MMA)
To enable the greatest possible breadth of applications, the following parameters can be adjusted
or optimised for the welding task.
To change the advanced setting parameters, hold down the "Welding parameters" button for
2 seconds after selecting the welding process.
The following diagram shows the setting options.
ENTER
2 s
EXIT
2 s
NAVIGATION
Pulse
PF Pulse
Pulse
PF Pulse
Figure 5-13
Display
Setting/selection
Arcforce correction (setting -10 to 10, factory setting 0)
• Increase value > harder arc
• Decrease value > softer arc
Frequency correction (setting: -99% to 99%, ex works: 0%)
Frequency correction of the PF Pulse parameter in per cent.
Balance correction (setting:
–99% to 99%, ex works: 0%)
Balance correction of the PF Pulse parameter in per cent
Pulse current correction (setting: -99% to 99%, ex works: 0%)
Pulse current correction of the PF Pulse parameter in per cent.
Frequency, MMA pulsed welding
Setting range: 0.2 Hz to 500 Hz (ex works: 5.0 Hz)
Balance
Percentage of time from pulse cycle Tpuls for pulse current IP1
Setting range 1%
–99%
Pulse current
Setting range 1%
–200%