Design and function
MMA welding
099-002129-EW501
15.10.2020
19
5.4.5 Antistick
The Antistick feature prevents the electrode from annealing.
Should the electrode stick despite the Arcforce feature, the machine au-
tomatically switches to the minimum current within approx. one second.
This prevents the electrode from annealing. Check the welding current
setting and correct for the welding task in hand.
Figure 5-10
5.4.6 Average value pulse welding
Average value pulse welding means that two currents are switched periodically, a current average value
(AMP), a pulse current (Ipuls), a balance (
) and a frequency (
) having been defined first. The
predefined ampere current average value is decisive, the pulse current (Ipuls) is defined by the
para-
meter as a percentage of the current average value (AMP). The pulse pause current (IPP) requires no
setting. This value is calculated by the machine control, so that the welding current average value (AMP)
is maintained at all times.
Figure 5-11
AMP = Main current; e.g. 100 A
Ipuls = Pulse current =
x AMP; e.g. 140% x 100 A = 140 A
IPP = Pulse pause current
Tpuls = Duration of one pulse cycle = 1/
; e.g. 1/1 Hz = 1 s
= Balance
Selection
Figure 5-12
For parameter setting,
> see 5.4.7 chapter
.