Design and function
Degaussing
099-002129-EW501
15.10.2020
27
The process must be activated before use. The subsequent restarting of the power source
switches back to the last active welding procedure.
+
Figure 5-25
Display
Setting/selection
Degaussing is activated.
Figure 5-26
• Press the welding procedure/ degaussing pushbutton.
• The signal light "A” flashes.
• Check the magnetic field on the workpiece with the magnetic field meter.
• Increase the current with the rotary transducer until the magnetic field in the component decreases
towards “0”.
If the field strength increases in the workpiece:
• Switch off activgauss.
• Change polarity by switching cables.
• Switch on activgauss.
• Increase the current with the rotary transducer until the magnetic field in the workpiece decreases to-
wards “0”.