Rectifying faults
Resetting JOBs (welding tasks) to the factory settings
100
099-004833-EW501
22.04.2013
7.3
Resetting JOBs (welding tasks) to the factory settings
NOTE
JOBs 1–128 and 170–256 will be reset.
Custom JOBs 129–169 are maintained.
Operating
element
Action Result
Display
1 x
Select “Special Mode”
Program steps
1 x
2 x
1 x
Special
Mode
Select Res. All using the buttons
“Up” and
“Down” (left).
Res. All 1
1 x
Save change
No change
1 x
Exit “Special Mode”
Last selected
parameters are
displayed
A