Design and function
MIG/MAG welding
099-004833-EW501
22.04.2013
65
5.10.11.1 Selecting parameters (program A) using wire feed unit control M3.19
Operating
element
Action Result
Display
2 x
Select main program A mode
Program A
n x
Select the welding parameters using the buttons
"Up" and
"Down" (left)
n x
Change values for the selected welding
parameter using the buttons
"Up" and
"Down" (right)
2 x
Machine returns to Display mode
5.10.11.2 Selecting parameters (program A) using wire feed unit control M3.70
Operating
element
Action Result
Display
n x
Change welding data display over to program
display.
(LED
PROG
is on)
Select program number.
Display example: Program "1".
n x
Select program sequence parameter
"Main program (P
A
)".
(LED is on)
Set wire speed.
(Absolute value)
Set arc length correction.
Display example: "-0.8 V" correction
(Setting range: -9.9 V to +9.9 V)
1 x
Select "Dynamic" program sequence parameter.
(LED
is on)
Set dynamic. (Setting range 40 to -40)
40:
Arc hard and narrow.
-40:
Arc soft and wide.
NOTE
Changes to the welding parameters can only be made when the key switch is in
position "1".
Program 0 (manual operation) is an exception;
this program can be modified at any time.
A
V
Job Nr
Hold
A
M
sec
sec
sec
sec
sec
sec
DYN
sec
sec
Super-
puls
m/min
DYN
sec
sec
sec
sec
sec
sec
DYN
sec
sec
Super-
puls
m/min