Design and function
MIG/MAG welding
099-004833-EW501
22.04.2013
63
5.10.11 Main program A mode
Different welding tasks or positions on a workpiece demand various welding performances (operating
points) or welding programs. The following parameters are stored in each of the up to 16 programs:
• Operating
mode
• Welding
type
• Superpulses
(ON/OFF)
• Wire feed speed (DV2)
• Voltage correction (U2)
• Dynamics
(DYN2)
NOTE
PIn the factory setting,
START
, P
B
, and P
END
are "relative programs". They relate to
percentages of the wire feed value from the main program P
A
.
Switching between relative and absolute wire feed values, see the "Switching WF speed
(absolute/relative)" chapter.
The user can change the main program welding parameters using the following components.
Progra
m
switching
Progra
m
Opera
ting
mod
e
Welding
me
thod
superPuls
Wire spe
e
d
Voltage
correc
tion
Dyna
mic
s
M3.19
Welding machine control
No
P0
No Yes
No
P1...15 Yes
M3.00
Wire feeder control
Yes
5)
P0 Yes
2)
No
Yes
1)
Yes
1)
Yes
1)
P1...15 No
No
M3.70
Wire feeder control
Yes
P0
Yes
Yes
1)
Yes
3)
P1...15 Yes
R20
Remote control
Yes
3)
P0
No
Yes
1)
No
P1...9 No
R40
Remote control
Yes
4)
P0
No
Yes Yes
3)
No
P1...15 Yes
R50
Remote control
Yes
4)
P0
Yes
Yes
1)
Yes
2)
P1...15 Yes
PC300.Net
Software
No
P0 Yes
No
P1...15 Yes
UP/DOWN
Welding torch
Yes
P0
No
Yes
No
P1...9 No
Powercontrol 1
Welding torch
Yes
P0
No
Yes
No
P1...15 No
Powercontrol 1 2D
Welding torch
Yes
P0
No
Yes
No
P1...15 No
Powercontrol 2
Welding torch
Yes
P0
No Yes
No
P1...15
1) Setting using rotary knob
2) Setting using changeover switch
3) Internal memory
4) Powercontrol torch not connected