Design and function
Transport and installation
20
099-005325-EW501
01.02.2017
5.1.5
Intermediate hose package connection
Some wire electrodes (e.g. self-shielding cored wire) are welded using negative polarity. In this
case, the welding current lead should be connected to the "-" welding current socket, and the
workpiece lead should be connected to the "+" welding current socket. Observe the information
from the electrode manufacturer!
Figure 5-1
Item Symbol
Description
0
1
Wire feed unit
2
Intermediate hose package
3
Intermediate hose package strain relief
4
7-pole connection socket (digital)
Wire feed unit connection
5
Connection socket, “+” welding current
• Standard MIG/MAG welding (intermediate hose package)
6
Connection socket, “-” welding current
• MIG/MAG cored wire welding:
Welding current to wire feed/torch
7
Quick connect coupling (red)
coolant return
8
Quick connect coupling (blue)
coolant supply