Design and function
MMA welding
32
099-005325-EW501
01.02.2017
5.4
MMA welding
CAUTION
Risk of being crushed or burnt.
When replacing spent or new stick electrodes
• Switch off machine at the main switch
• Wear appropriate safety gloves
• Use insulated tongs to remove spent stick electrodes or to move welded workpieces and
• Always put the electrode holder down on an insulated surface.
5.4.1
Connecting the electrode holder and workpiece lead
Polarity depends on the instructions from the electrode manufacturer given on the electrode
packaging.
Figure 5-13
Item Symbol
Description
0
1
Connection socket, “+” welding current
2
Connection socket, “-” welding current
3
Workpiece
4
Electrode holder
• Insert cable plug of the electrode holder into either the "+" or "-" welding current connection socket and
lock by turning to the right.
• Insert cable plug of the workpiece lead into either the "+" or "-" welding current connection socket and
lock by turning to the right.
5.4.2
Welding task selection
For selection of the welding task and for general operation see the relevant Wire feeder
instructions.