Design and function
MIG/MAG welding
099-005183-EW501
17.12.2010
39
The correct wire speed is not known and is to be determined.
• Select the appropriate JOB (see "JOB list" sticker)
• Switch to the material thickness display
• Set the material thickness as appropriate (e.g. 5 mm)
• Switch to the wire speed display
The resulting wire speed will be shown (e.g. 8.4 m/min).
5.7.8.2
Operating point setting using material thickness, welding current, wire speed
Given below is a description of the setting work via the wire speed parameters as an example of
operating point setting.
Operating
element
Action Result
Display
m/min
Increase or reduce welding performance via the
wire speed parameter.
Display example: 10.5 m/min
5.7.8.3
Arc length correction setting
The arc length can be corrected as follows.
Operating
element
Action Result
Display
"Arc length correction" setting
(Display example: -0.9V,
setting range -9.9 V to +9.9 V)
5.7.8.4
Accessory components for operating point setting
The operating point can also be set with various accessory components such as
• remote
controls
• special
torches
• PC
software
• robot and industrial bus interfaces (optional mechanised welding interface required – not possible for
all machines in this series!)
You will find an overview of accessory components in the "Accessories" chapter. See the operating
instructions for the machine in question for a more detailed description of the individual machines and
their functions.