Design and function
MIG/MAG welding
099-005183-EW501
17.12.2010
57
5.7.14.2
MIG/MAG
overview of parameters
sec
sec
sec
sec
sec
sec
DYN
sec
sec
Super-
puls
6
7
4
3
2
1
10
5
9
14
11
12
8
13
Figure 5-28
Basic Parameters
Item
Meaning / Explanation
Setting Range
1
Gas pre-flow time
0.0s to 20.0s
2 P
START
Wire speed, relative
Arc length correction
1% to 200%
-9.9V to +9.9V
3
Duration
0.0s to 20.0s
4
Slope duration from P
START
to P
A
0.0s to 20.0s
5 P
A
Wire speed, absolute
0.1 m/min to 40 m/min
6 Dynamics
-40
to
+40
7
Duration (spot time and superpulse)
0.01s to 20.0s
8 P
B
Wire speed, relative
Arc length correction, relative
1% to 200%
-9.9V to +9.9V
9 Duration
0.01s
to
20.0s
10
Slope duration from P
A
to P
END
0.0s to 20s
11 P
END
Wire speed, relative
Arc length correction
1% to 200%
-9.9V to +9.9V
12
Duration (superpulse)
0.0s to 20s
13
Gas post-flow time
0.0s to 20s
14 Superpulses
On
/
Off
NOTE
In the factory setting, P
START
, P
B
, and P
END
are "relative programs". They relate to
percentages of the wire feed value from the main program P
A
.