Design and function
MIG/MAG welding
60
099-005183-EW501
17.12.2010
5.7.14.6
Example, visible seams (latched super pulse)
t
I
P
A
P
A
P
A
P
A
P
B
P
B
P
B
P
END
P
START
Figure 5-32
Basic parameters
Welding parameter
Meaning / explanation
Setting range
GASstr
Gas pre-flow time
0.0s to 20.0s
GASend:
Gas post-flow time
0.0s to 20.0s
RUECK
Wire burn-back length
2 to 500
PROC.SP.
Travel speed to determine the a-measurement*
10cm to 200cm
"P
START
" start program
Welding parameter
Meaning / explanation
Setting range
DVstart
Wire speed
0% to 200%
ustart
Arc length correction
-9.9V to +9.9V
tstart Duration
0.0s
to
20s
"P
A
" main program
Welding parameter
Meaning / explanation
Setting range
tS1
Slope duration from P
START
to P
A
0.0s
to
20s
DV3
Setting the wire speed
0% to 200%
t2 Duration
0.1s
to
20s
tS3
Slope duration from P
B
to P
A
0.0s
to
20s
"P
B
" reduced main program
Welding parameter
Meaning / explanation
Setting range
tS2
Slope duration from P
A
to P
B
0.0s
to
20s
DV3
Wire speed
0% to 200%
U3
Arc length correction
-9.9V to +9.9V
t3 Duration
0.1s
to
20s
"P
END
" end-crater program
Welding parameter
Meaning / explanation
Setting range
tSend
Slope duration from P
A
or P
B
to P
END
0.0s
to
20s
DVend
Wire speed
0% to 200%
Uend
Arc length correction
-9.9V to +9.9V
tend Duration
0.0s
to
20s