background image

 

Accessories 

Options 

 

099-008268-EW501 

21.02.2022

 

29

 

 

11  Accessories 

11.1  Options 

Type 

Designation 

Item no. 

ON FILTER COOL 

Air inlet dirt filter, retrofit option 

092-008771-00000 

 

11.2  Welding torch cooling system 

11.2.1  Coolant - type blueCool 

Type 

Designation 

Item no. 

blueCool -10 5 l 

Coolant up to -10 °C (14 °F), 5 l 

094-024141-00005 

blueCool -10 25 l 

Coolant up to -10 °C (14 °F), 25 l 

094-024141-00025 

blueCool -30 5 l 

Coolant up to -30 °C (22 °F), 5 l 

094-024142-00005 

blueCool -30 25 l 

Coolant up to -30 °C (22 °F), 25 l 

094-024142-00025 

FSP blueCool 

Frost protection tester 

094-026477-00000 

 

11.2.2  Coolant - type KF 

Type 

Designation 

Item no. 

KF 23E-5 

Coolant up to -10 °C (14 °F), 5 l 

094-000530-00005 

KF 23E-200 

Coolant (-10 °C), 200 litres 

094-000530-00001 

KF 37E-5 

Coolant up to -20 °C (4 °F), 5 l 

094-006256-00005 

KF 37E-200 

Coolant (-20 °C), 200 l 

094-006256-00001 

TYP1 

Frost protection tester 

094-014499-00000 

 

Содержание cool82 U44

Страница 1: ...Operating instructions EN Air cooling units for water cooled welding torches cool82 U44 cool82 U45 099 008268 EW501 Observe additional system documents 21 02 2022...

Страница 2: ...to the operation of this equipment is restricted solely to the function of the equipment No other form of liability regardless of type shall be accepted This exclusion of liability shall be deemed ac...

Страница 3: ...3 Transport and installation 17 5 3 1 Machine cooling 17 5 3 2 Ambient conditions 17 5 3 3 Welding torch cooling system 18 6 Functional characteristics 19 6 1 1 1 Permitted torch coolant 19 6 1 1 2 Ma...

Страница 4: ...s and even fatal injuries Safety notes include the WARNING keyword in the heading with a general warning sym bol The hazard is also highlighted using a symbol in the page margin CAUTION Working or ope...

Страница 5: ...tch off machine Release Switch on machine Press and hold Switch Incorrect Invalid Turn Correct Valid Numerical value adjustable Input Signal light lights up in green Navigation Signal light flashes gr...

Страница 6: ...cal specialist may interconnect the sources as per standard IEC 60974 9 2010 Installa tion and use and German Accident Prevention Regulation BVG D1 formerly VBG 15 or country specific regulations Befo...

Страница 7: ...temperatures of 100 C or higher and arcing and work on live components Hearing protection against harming noise Explosion risk Apparently harmless substances in closed containers may generate excessi...

Страница 8: ...s specified in the standard The user is responsible for any interference caused by welding In order to evaluate any possible problems with electromagnetic compatibility in the surrounding area the use...

Страница 9: ...placement parts etc from our range of products Only insert and lock accessory components into the relevant connection socket when the ma chine is switched off Requirements for connection to the public...

Страница 10: ...on or connection points can heat up significantly during operation water cooled version When opening the coolant circuit escaping coolant may cause scalding Open the coolant circuit only when the powe...

Страница 11: ...ire feed unit The following system components can be combined with this machine alpha Q 352 552 Phoenix 352 452 552 Tetrix 352 452 552 tigSpeed 352 Synergic RC HW 3 3 Documents which also apply 3 3 1...

Страница 12: ...perating instructions for all system components especially the safety instructions The illustration shows a general example of a welding system Figure 3 1 Item Operating instructions A 1 Wire feeder m...

Страница 13: ...overview 4 1 Front view Figure 4 1 Item Symbol Description 0 1 Tension closure Connection between the add on module and the welding machine 2 Coolant tank cap 3 Coolant tank see 5 3 3 chapter 4 Coolin...

Страница 14: ...iption 0 1 Cooling air outlet 2 Connector plug 8 pole Cooling unit control lead 3 Connector plug 5 pole Cooling unit voltage supply 4 Quick connect coupling blue Coolant supply to the welding torch 5...

Страница 15: ...and accessories that are not properly fastened to trans port systems may tip over during transport and cause injury Use the systems only for transporting the machines specified in Secure the machines...

Страница 16: ...wn in fig Figure 5 3 Engage the locking hook in the recesses in the side walls of the welding machine Turn the wing tip handle clockwise B2 to close the fastening Lay the wing tip handle down flat C2...

Страница 17: ...d action closure coupling supply of coolant to the welding torch Control and supply lead to the welding machine The cooling module and welding machine are connected using two leads Insert control lead...

Страница 18: ...suitable coolants Unsuitable coolant coolants mixed with other types liquids or use in an unsuitable tempera ture range will result in material damage and loss of the manufacturer s warranty Operation...

Страница 19: ...ry configurations of components of the EWM product portfolio with standard lengths A straight kink free installation is to be ensured taking into account the max delivery height Pump Pmax 3 5 bar 0 35...

Страница 20: ...ng cover Check filter sieve insert for dirt clean if necessary and reinsert into position Top up coolant to the filter sieve insert close sealing cover again The level of coolant must never fall below...

Страница 21: ...e only The welding machine automatically detects and displays a lack of coolant see the welding machine operating instructions 7 1 1 Welding torch connection Overloading the coolant pump The cooling u...

Страница 22: ...ce matters always consult the dealer who supplied the machine Return deliveries of defective equipment subject to warranty may only be made through your dealer When replacing parts use only original s...

Страница 23: ...rollers on a regular basis depending on the degree of soiling 8 2 2 Monthly maintenance tasks Visual inspection Casing damage front rear and side walls Wheels and their securing elements Transport ele...

Страница 24: ...tem separate from unsorted municipal waste The public waste management utilities communities have created collection points at which used equipment from private households can be disposed of free of...

Страница 25: ...cription Fault Cause Remedy Coolant error no coolant flowing Insufficient coolant flow Check coolant level and refill if necessary Eliminate kinks in conduit system hose packages Extend and lay out th...

Страница 26: ...personnel Risk of injury from electrical voltage Voltages can cause potentially fatal electric shocks and burns on contact Even low vol tages can cause a shock and lead to accidents Never touch live c...

Страница 27: ...max Pump pressure 3 5 bar 0 35 MPa Pump Centrifugal pump max Tank content 7 5 l 2 0gal Protection class Overvoltage category Contamination level 3 Coolant see 6 1 1 1 chapter Machine cooling protectio...

Страница 28: ...ank content 7 5 l 2 0gal Protection class Overvoltage category Contamination level 3 Coolant see 6 1 1 1 chapter Machine cooling protection classification Fan AF IP 23 Noise level 2 70 dB A EMC class...

Страница 29: ...10 25 l Coolant up to 10 C 14 F 25 l 094 024141 00025 blueCool 30 5 l Coolant up to 30 C 22 F 5 l 094 024142 00005 blueCool 30 25 l Coolant up to 30 C 22 F 25 l 094 024142 00025 FSP blueCool Frost pro...

Страница 30: ...ndix Searching for a dealer 30 099 008268 EW501 21 02 2022 12 Appendix 12 1 Searching for a dealer Sales service partners www ewm group com en specialist dealers More than 400 EWM sales partners world...

Отзывы: