Functional characteristics
Transport and installation
099-008268-EW501
21.02.2022
19
6
Functional characteristics
The cooling modules (pump and fan) are controlled by the welding machine only.
The welding machine automatically detects and displays a lack of coolant
(see the welding machine operating instructions).
6.1.1.1 Permitted torch coolant
Coolant
Temperature range
blueCool -10
-10 °C to +40 °C (14 °F to +104 °F)
KF 23E (Standard)
-10 °C to +40 °C (14 °F to +104 °F)
KF 37E
-20 °C to +30 °C (-4 °F to +86 °F)
blueCool -30
-30 °C to +40 °C (-22 °F to +104 °F)
6.1.1.2 Maximal hose package length
All information relates to the total hose package length of the complete welding system and presents
exemplary configurations (of components of the EWM product portfolio with standard lengths). A straight
kink-free installation is to be ensured, taking into account the max. delivery height.
Pump: Pmax = 3.5 bar (0.35 MPa)
--------------------------------------------------------------------------------------------------------------------- ►
Power source
Hose package
Wire feeder miniDrive
Welding torch
max.
Compact
(25 m / 82 ft.)
(5 m / 16 ft.)
30 m
98 ft.
(20 m / 65 ft.)
(5 m / 16 ft.)
Decompact
(25 m / 82 ft.)
(5 m / 16 ft.)
(15 m / 49 ft.)
(10 m / 32 ft.)
(5 m / 16 ft.)
6.1.1.3 Adding coolant
If the cooling system is empty or only insufficiently filled with coolant, the coolant pump is auto-
matically switched off after approx. one minute (protection against destruction). At the same
time, the welding data display signals the lack of coolant or low coolant level.
• Reset the coolant error, fill coolant and repeat the operation.
The unit is supplied ex works with a minimum level of coolant.
Figure 6-1
Item Symbol Description
0
1
Coolant tank cap