Warranty 

Warranty Declaration 

 

18 

Item No.: 099-008088-EWM01

 

 

8.2

 

Warranty Declaration 

 

Your 3-year warranty 

Regardless of statutory warranty rights and based on our General Terms and Conditions, 

EWM 

HIGHTEC WELDING GmbH provides a 3-year warranty for its welding products starting on the date of 
purchase. Different warranty periods apply to accessories and spare parts; please see the “General 
Validity” section for these periods. Parts subject to wear are naturally exempt from the warranty. 

EWM guarantees the error-free condition of the products in terms of materials and processing. If the 
product proves to be defective in terms of materials or processing within the warranty period, you are 
entitled to free repair or to replacement with an appropriate product, at our discretion. On receipt by EWM 
the returned product becomes the property of EWM. 

 

Condition 
The prerequisite for receiving the full 3-year warranty is simply to operate the products in accordance with 
the EWM operating instructions observing the relevant legal recommendations and guidelines and having 
annual maintenance work and testing conducted by an EWM sales partner (see “Maintenance and 
testing” chapter). This is because only machines that are maintained regularly function correctly in the 
long term. 

 

Making a claim 
When making a claim under the warranty, please contact your EWM authorised sales partner only. 

 

Warranty exclusions 
No warranty claims can be accepted if the EWM products in question are not operated using genuine 
EWM accessories (such as intermediate tube package, remote control, remote control extension cable, 
coolant, etc.). The warranty does not apply to products that are damaged due to accidents, misuse, 
improper operation, incorrect installation, use of force, disregard of the specifications and operating 
instructions, inadequate maintenance (see chapter “Maintenance and testing”), exterior influences, acts of 
God or personal misfortunes. Furthermore, it is not valid in the case of improper changes, repairs or 
modifications. In addition, a claim for warranty does not exist in the case of partially or completely 
dismantled products and interventions by persons who are not authorised by EWM, as well as in the case 
of normal wear. 

 

Limitation 
All claims regarding fulfilment or non-fulfilment on the part of EWM from this declaration in connection 
with this product are limited as follows to the replacement of the actual damages. EWM’s liability 
stemming from this declaration in connection with this product is fundamentally limited to the amount that 
the purchaser originally paid for the original purchase. This limitation does not apply to personal injuries 
or damage to property caused by negligent behaviour on the part of EWM. In no way will EWM be 
responsible for lost profits, indirect or subsequent damage. EWM is not liable for damages based on the 
claims of third parties. 

 

Place of jurisdiction 
If the person making the claim is a business person, the sole place of jurisdiction for all disputes resulting 
directly or indirectly from the contractual relationship shall be the headquarters or the branch office of the 
supplier, at the discretion of the supplier. The purchaser gains ownership of the products supplied as 
replacements within the framework of the warranty adjustment at the time of the exchange. 

Содержание PHOENIX R10

Страница 1: ...ate safety regulations The machines bear the conformity mark and thus comply with the EC Low Voltage Directive 2006 95 EG EC EMC Directive 2004 108 EG In compliance with IEC 60974 EN 60974 VDE 0544 the machines can be used in environments with an increased electrical hazard The content of the operating instructions does not constitute grounds for any claims on the part of the buyer The copyright t...

Страница 2: ...body future oriented advanced technology at the utmost level of quality Each of our products is carefully checked we guarantee that the material and processing of our products is faultless These operating instructions contain everything about commissioning the machine notes regarding safety maintenance and care technical data as well as information regarding the warranty Please heed all these note...

Страница 3: ...fields CE EWM HIGHTEC WELDING GMBH D 56271 MÜNDERSBACH TYP ART SNR PROJ GEPRÜFT CONTROL Name of Customer company Adress Post code Place Country Stamp Signature of EWM distibutor Date of purchase Name of Customer company Adress Post code Place Country Stamp Signature of EWM distibutor Date of purchase 3 ...

Страница 4: ...program down parameter 12 5 2 2 4 Changing over between standard MIG welding and pulse arc MIG welding 13 5 2 2 5 Operating point setting changeover via wire feed speed or panel thickness 13 5 3 Switching on and system diagnosis 13 5 3 1 R40 manual remote control 13 6 Commissioning 14 6 1 Proper usage 14 6 1 1 For operation only with the following equipment 14 6 2 Establishing the connections 14 7...

Страница 5: ...Contents For your safety Item No 099 008088 EWM01 5 ...

Страница 6: ... these operating instructions These operating instructions are arranged into chapters To help you find your way around more quickly in the margins you will occasionally see symbols along with the sub headings These symbols refer to particularly important passages of text which are graded as follows depending on their importance Please note Technical features which users must observe Warning Workin...

Страница 7: ...088 EWM01 7 3 Technical data 3 1 PHOENIX R10 R20 R40 Type R10 R20 R40 Port 19 pole analogue 19 pole analogue 7 pole digital Display Single digit 16 digit Dimensions L x W x H in mm 180 x 100 x 75 330 x 180 x 95 270 x 150 x 75 Weight in kg 0 86 2 3 1 4 ...

Страница 8: ... features Setting the operating point via the wire speed single dial operation Arc length correction PHOENIX R20 Changeover and display of up to ten welding programs PHOENIX R40 Change over display create or change up to 16 welding programs Switch superpulse function on or off Change over between standard MIG welding and pulse arc MIG welding if supported by the welding machine 4 2 PHOENIX R10 R20...

Страница 9: ...ey button program switching Down Select program number down 8 500A 49 9V Display 16 digit Display of all welding parameters and their values 9 Key button Mode To select the program runtime parameters 10 Signal light HOLD Lit Display shows the last parameters used for welding Not lit Display shows the setpoint values or current values during welding 11 Key button program switching Up Select program...

Страница 10: ...g parameters The wire speed is generally used to set the operating point In the situations given below the wire speed is given to represent the operating point Operating element Action Result Display R40 R10 R20 m min R40 Operating point setting via wire speed Display example Wire speed 7 6 m min Display for PHOENIX R40 only P0 7 6M 1 1V The arc length can be corrected as follows Operating element...

Страница 11: ...ol 5 2 2 1 Program changeover Change between up to 16 0 to 15 welding programs Welding programs can be created using the control on the welding machine or wire feed unit or using the remote control itself see operating instructions for the relevant machine chapter Main program mode A or the chapters following these instructions Operating element Action Result Display Select next or previous weldin...

Страница 12: ...START PA PA PB PEND t I Figure 5 1 Start program PSTART DVstart Wire feed speed relative 1 to 200 Ustart Arc length correction 9 9 V to 9 9 V tstart Duration 0 0 s to 20 0 s Main program PA tS1 Slope duration from PSTART to PA 0 0 s to 20 0 s t2 Duration spot time and superpulse 0 01 s to 20 0 s tS2 Slope duration from PA to PB 0 00 s to 20 0 s Reduced main program PB DV3 Wire feed speed relative ...

Страница 13: ... Operating element Action Result Display Switch off the welding machine Hold down Mode button on the remote control switching on the welding machine PROGRAMME 0XX Press Mode button once DV Operating point setting changeover via wire speed or panel thickness DV Wire speed th mm Panel thickness th mm Switch off the welding machine and restart in order to put the change into effect 5 3 Switching on a...

Страница 14: ...ons for the welding machine or wire feed unit Switch off the welding machine first 6 1 1 For operation only with the following equipment PHOENIX R10 PHOENIX R20 PHOENIX R40 PHOENIX BASIC PHOENIX PROGRESS PHOENIX EXPERT PHOENIX PROGRESS PHOENIX EXPERT PHOENIX PROGRESS PHOENIX EXPERT PHOENIX R20 An M3 70 or M3 71 type wire feed control is mandatory 6 2 Establishing the connections 1 2 3 6 4 5 Figure...

Страница 15: ...e 4 19 pole connection socket analogue For connecting the control lead 5 Connector plug 19 pole female 6 Connector plug 19 pole male Switch off the welding machine Insert female connector plug into the remote control connection socket and lock by turning to the right Insert male connector plug into the remote control connection socket on the welding machine and lock by turning to the right The wel...

Страница 16: ...ection points Your administrative office will be pleased to inform you of the options EWM participates in an approved waste disposal and recycling system and is registered in the Used Electrical Equipment Register EAR under number WEEE DE 57686922 In addition within Europe the machine can also be returned to your EWM sales partner 7 4 1 Manufacturer s declaration to the end user In accordance with...

Страница 17: ...All additional parts used by EWM but manufactured by other companies e g motors pumps fans torches etc Non reproducible software errors and parts subject to mechanical ageing are excluded from the warranty e g wire feed unit wire feed rollers replacement and spare wire feed parts wheels solenoid valves workpiece leads electrode holders connection tubes replacement torches and spare torch parts mai...

Страница 18: ...e remote control remote control extension cable coolant etc The warranty does not apply to products that are damaged due to accidents misuse improper operation incorrect installation use of force disregard of the specifications and operating instructions inadequate maintenance see chapter Maintenance and testing exterior influences acts of God or personal misfortunes Furthermore it is not valid in...

Страница 19: ... 19POL 5M Remote control e g connection cable 092 001470 00005 RA10 19POL 10M Remote control e g connection cable 092 001470 00010 RA20 19POL 20M Remote control e g connection cable 092 001470 00020 FRV5 L 7POL Extension connecting cable 092 000201 00003 FRV10 L 7POL Extension connecting cable 092 000201 00000 FRV20 L 7POL Extension connecting cable 092 000201 00001 ...

Страница 20: ...Circuit diagrams PHOENIX R10 20 Item No 099 008088 EWM01 10 Circuit diagrams 10 1 PHOENIX R10 Figure 10 1 ...

Страница 21: ...D C LED F NC 0V 0V T T T T T T T T T T T K A V7 T K A V3 T K A V5 T K A V6 1 X3 2 X3 3 X3 4 X3 5 X3 6 X3 7 X3 8 X3 9 X3 10 X3 X3 1 X3 2 X3 3 X3 4 X3 5 X3 6 X3 7 X3 8 X3 9 X3 10 X3 10 X3 0V 1 2 3 4 Uref 10V 0V UKorr UKorr X2 2 V2 0V S P2 US E A S P1 DV 1 P2 0V 1 P2 0V 4k7 4k7 E A 2 Down 1 Up 3 T 4 T DV US 1 PE 2n2F C1 1 F A D G B C E gemeinsame Kathode 10k 10k Datum Name gezeichnet geprüft Freigabe...

Страница 22: ...2 1 X2 2 X2 3 X2 4 X2 R40 A1 1 42VAC 2 RSGND 3 RXD 4 TXD 5 RS 12V 6 0V ws br gn ge gr rs Schirm 1 2 3 4 5 6 7 X1 2n2F C1 1 2 T 3 Schlüsselschalter S1 4 3 2 T 3 T Datum Name gezeichnet geprüft Freigabe 24 05 2005 NIEDENTHAL Blatt 1 This drawing is protected by copyright It may not be reproduced or utilised in any way or communicated or forwarded to third parties without our express permission 1 PHO...